What are AC DC Converters ?
AC DC Converters are electronic devices that convert alternating current (AC) into direct current (DC), enabling the operation of DC-powered devices. They are widely used in applications such as industrial power management, power conversion subsystems, and maintenance and field replacement. Important specifications for selection include Efficiency, which impacts energy consumption; Current, which determines the load capacity; and Operating Temperature, which ensures reliability under varying environmental conditions. Procurement teams should validate lifecycle status and consider alternate-source options to mitigate sourcing risks.
Parts in this category
Tap rows to select parts
Compare stocked parts across manufacturers and distributors, then add lines to your RFQ.
| Part & Mfr | AEC Qualified | Applications | Approval Agency | Automotive Grade | Class | Compliance | Current | Dimensions | Duration | Efficiency | Features | Frequency | Height | Industrial Grade | Input Frequency | Input Voltage | Isolation | Length | Medical Grade | Military Grade | Mounting Type | No Load Power Consumption | Number of Outputs | Operating Temperature | Output Current | Output Power | Output Voltage | Overload Protection | Package / Case | Power | Power (Watts) | SVHC Present | Size | Standard Number | Storage Temperature | Tape & Reel | Temperature Coefficient | Termination Style | Type | Voltage | Width | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Morning Star Industrial
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus | - | - | - | 1.33A | - | - | 83% | Adjustable Output | - | - | - | - | - | - | - | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | 8-DIP Module, 4 Leads | - | 20W | - | - | 62368-1 | - | - | - | - | Enclosed | 90 ~ 528 VAC, 100 ~ 745 VDC | - | |
Delta Electronics
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, UL | - | - | - | 250mA | - | - | 75% | Universal Input | - | 17.1mm (0.67") | - | 47-440 Hz | 85-264 VAC | 3 kVAC | 36.5mm (1.44") | - | - | Through Hole | 0.3 W | 2 | -25°C ~ 60°C | - | - | - | - | 7-DIP Module | - | 4 W | - | - | 60950-1 | - | - | ±0.01 ~ ±0.02 %/℃ | - | Enclosed | +5 VDC | 27.0mm (1.06") | |
|
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CB, CE, cULus, cURus | - | - | - | 1.25A | - | - | 79% | Universal Input | - | 19.5mm (0.77") | - | - | - | - | 74.0mm (2.91") | - | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | - | - | 15 W | - | - | - | - | - | - | - | Enclosed | 12 VDC / 1.25A / 15 W / 79% / -25°C ~ 70°C (With Derating) / 74.0mm (2.91") / 54.0mm (2.13") / 19.5mm (0.77") / 47-440 Hz / Class II / Over-temperature protection / Short circuit protection / Overload protection / 3-year product warranty | 54.0mm (2.13") | |
|
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus, FCC, TUV | - | - | - | 1.67A | - | - | 85% | Universal Input | - | 32.4mm (1.27") | - | - | - | - | 101.6mm (4.00") | - | - | Through Hole | - | 1 | 0°C ~ 70°C (With Derating) | - | - | - | - | - | - | 40 W | - | - | 62368-1 | - | - | - | - | Open Frame | 90 ~ 264 VAC | 50.8mm (2.00") | |
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, CSA, cURus | - | - | - | 2.667A | - | - | 90% | Standby Output, Universal Input | - | 28.9mm (1.14") | Yes | - | - | 4kVAC | 78.3mm (3.08") | Yes | - | Through Hole | - | 1 | -40°C to +60°C ambient | - | - | 15 VDC | - | 7-DIP Module, 6 Leads | - | 40 W | - | - | - | - | - | - | - | Open Frame | 80-264 VAC | 40.6mm (1.60") | |
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, CSA, cURus | - | - | - | 833mA | - | - | 90% | Standby Output, Universal Input | - | 28.9mm (1.14") | - | - | - | - | 78.3mm (3.08") | - | - | Through Hole | - | 1 | -40°C ~ 85°C (With Derating) | - | - | 48 VDC | - | Open Frame | - | 40 W | - | - | - | - | - | - | 7-DIP Module, 6 Leads | Open Frame | 100-240 VAC | 40.6mm (1.60") | |
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, CSA, cURus | - | - | - | 1111 mA | - | - | 90% | Standby Output, Universal Input | - | 28.9mm (1.14") | - | - | - | 4kVAC | 78.3mm (3.08") | Yes | - | Through Hole | - | 1 | -40°C ~ 85°C (With Derating) | - | - | 36 VDC | - | 7-DIP Module, 6 Leads | - | 40 W | - | - | - | - | - | - | - | Open Frame | 120-370 VDC | 40.6mm (1.60") | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Household Appliances, ITE (Commercial) | CB, CE, cURus | - | - | - | 210mA | - | - | 84% | Universal Input | - | 15.7mm (0.62") | - | - | - | - | 38.1mm (1.50") | - | - | Through Hole | < 0.15 W | 1 | -25°C / 70°C | - | - | - | - | 4-DIP Module | - | 10 W | - | - | - | - | - | ±0.02%/K | - | Enclosed | 48 VDC | 25.4mm (1.00") | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Household Appliances, ITE (Commercial) | CB, CE, cURus | - | - | - | 1.1A | - | - | 83% | Universal Input | - | 15.7mm (0.62") | - | - | - | - | 38.1mm (1.50") | - | - | Through Hole | < 0.15 W | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | 4-DIP Module | - | 10 W | - | - | - | - | - | ±0.02 %/K max. | - | Enclosed | 9 VDC | 25.4mm (1.00") | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Household Appliances, ITE (Commercial) | CB, CE, cURus | - | - | - | 410mA | - | - | 86% | Universal Input | - | 15.7mm (0.62") | - | - | - | - | 38.1mm (1.50") | - | - | Through Hole | < 0.15 W | 1 | -25°C ~ 70°C | - | - | - | - | 4-DIP Module | - | 10 W | Not Present | - | - | - | - | - | - | Enclosed | 24 VDC | 25.4mm (1.00") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial), Medical | CE, cURus, TUV | - | - | - | 900mA | - | - | 85% | Universal Input | - | 20.4mm (0.80") | Yes | - | - | - | 64.2mm (2.53") | Yes | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | - | - | 22 W | - | - | 60601-1; 60950-1 | - | - | - | - | Enclosed | 90 ~ 264 VAC | 44.2mm (1.74") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial), Medical | CE, cURus, TUV | - | - | - | 1.7A | - | - | 83% | Universal Input | - | 20.4mm (0.80") | - | - | - | - | 64.2mm (2.53") | - | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | - | - | 20 W | - | - | 60601-1; 60950-1 | - | - | - | - | Enclosed | 90 ~ 264 VAC | 44.2mm (1.74") | |
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus | - | - | - | 333mA | - | - | 76% | - | - | 17.5mm (0.69") | - | - | - | - | 37.1mm (1.46") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | - | - | 4 W | Not Present | - | - | - | - | - | - | Enclosed | 90 ~ 305 VAC | 27.4mm (1.08") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial), Medical | CE, cURus, TUV | - | - | - | 2.3A | - | - | 81% | Universal Input | - | - | Yes | - | - | - | - | Yes | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | - | - | 21 W | - | - | 60601-1; 60950-1 | - | - | - | - | Enclosed | 90 ~ 264 VAC | - | |
|
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus | - | - | - | 1.2A | - | - | 68% | - | - | 17.5mm (0.69") | - | - | - | - | 37.1mm (1.46") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | - | - | 4 W | - | - | - | - | - | - | - | Enclosed | 90 ~ 305 VAC | 27.4mm (1.08") | |
|
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus | - | - | - | 500mA | - | - | 74% | - | - | 17.5mm (0.69") | - | - | - | - | 37.1mm (1.46") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | - | - | 4 W | - | - | - | - | - | - | - | Enclosed | 90 ~ 305 VAC | 27.4mm (1.08") | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Household Appliances, ITE (Commercial), Medical | CB, CE, cURus | - | - | - | 840mA | - | - | 90% | Adjustable Output, Universal Input | - | 24.1mm (0.95") | Yes | - | - | - | 69.7mm (2.74") | Yes | - | Through Hole | <60 mW | 1 | -40°C ~ 85°C (With Derating) | - | - | - | - | 5-DIP Module | - | 30 W | - | - | - | - | - | - | - | Open Frame | 36 VDC | 34.6mm (1.36") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus, FCC, TUV | - | - | - | 2.5A | - | - | 86% | Universal Input | - | 32.4mm (1.27") | - | - | 90 ~ 264 VAC | - | 101.6mm (4.00") | - | - | Through Hole | - | 1 | 0°C ~ 70°C (With Derating) | - | - | 24V | - | - | - | 60 W | - | - | 62368-1 | - | - | - | - | Open Frame | 90 ~ 264 VAC | 50.8mm (2.00") | |
|
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, CSA, cURus, EAC | - | - | - | 833 mA | - | - | 90% | Baseplate, Standby Output, Universal Input | - | 30.4mm (1.20") | - | - | - | 4kVAC / 1min | 83.2mm (3.28") | - | - | Through Hole | - | 1 | -40°C ~ 85°C (With Derating) | - | - | 48 VDC | - | 6-DIP Module | - | 40 W | - | - | - | - | - | - | - | Enclosed | 80 ~ 264 VAC | 46.4mm (1.83") | |
|
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, CSA, EN, UL | - | - | - | - | - | - | 75% | Universal Input | - | 22.9mm (0.90") | - | - | - | - | 61.0mm (2.40") | - | - | Through Hole | - | 1 | 0°C ~ 70°C (With Derating) | - | - | - | - | - | - | 10 W | - | - | 60950-1 | - | - | - | - | Open Frame | 85 ~ 264 VAC | 39.4mm (1.55") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus, FCC, Nemko | - | - | - | 1.67A | - | - | 89% | Universal Input | - | 34.2mm (1.35") | - | - | - | - | 50.8mm (2.00") | - | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | 36V | - | - | - | 60.12W | - | - | 62368-1 | - | - | - | - | Open Frame | 90 ~ 264 VAC | 50.8mm (2.00") | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
No | ITE (Commercial) | CE, cURus | No | - | - | 583mA | - | - | 80% | Universal Input | - | 18.7mm (0.74") | No | - | - | - | 27.4mm (1.08") | No | No | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | - | - | 7 W | - | - | - | - | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | 27.4mm (1.08") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus, FCC, Nemko | - | - | - | 5A | - | - | 88% | Universal Input | - | 34.2mm (1.35") | Yes | - | - | - | 50.8mm (2.00") | - | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | 12V | - | - | - | 60 W | Not Present | - | 62368-1 | - | - | - | - | Open Frame | 90 ~ 264 VAC | 50.8mm (2.00") | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CB Scheme, EN, IEC, UL | - | - | - | 1.6 A | - | - | up to 85 % | Universal Input | 47 ~ 63 Hz | 24.0mm (0.94") | - | - | - | - | 70.0mm (2.75") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | - | 20 W | 20 W | - | - | 55024; 55032 Class A; 60950-1; 61000-3-2; 61000-3-3 | - | - | ±0.02 %/°C | - | Enclosed | 12 Vdc | 48.0mm (1.89") | |
CUI Inc.
|
Send RFQ
|
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CB Scheme, EN, IEC, UL | - | - | - | 1.3 A | - | - | 83% | Universal Input | - | 24.0mm (0.94") | - | 47 ~ 63 Hz | - | - | 70.0mm (2.75") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | 15 V | - | - | - | 20 W | - | - | 55024; 55032 Class A; 60950-1; 61000-3-2; 61000-3-3 | -40°C ~ 105°C | No | ±0.02%/°C | - | Enclosed | 85 ~ 264 VAC | 48.0mm (1.89") | |
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE | - | - | - | 350mA | - | - | 75% | Universal Input | - | 21.5mm (0.85") | - | - | - | - | 38.1mm (1.50") | - | - | Through Hole | - | 1 | -10°C ~ 85°C (With Derating) | - | - | - | - | - | - | 5 W | - | - | - | - | - | - | - | Enclosed | 85 ~ 265 VAC, 120 ~ 370 VDC | 25.4mm (1.00") | |
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cULus | - | - | - | 1.2A | - | - | Up to 79% | SCP | - | - | - | - | - | - | - | - | - | Through Hole | 100mW | 1 | -40°C ~ 80°C | - | - | 3.3 VDC | - | 7-DIP Module, 6 Leads | - | 4 W | - | - | - | - | - | - | - | Enclosed | 113 ~ 373 VDC | - | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial), Medical | CE, cURus, FCC, TUV | - | - | - | 3.34A | - | - | 86% | Universal Input | - | 25.0mm (0.98") | Yes | - | - | - | 76.2mm (3.00") | Yes | - | Through Hole | - | 1 | -20°C ~ 70°C (With Derating) | - | - | - | - | 6-DIP Module | - | 40 W | Not Present | - | 60601-1; 60950-1 | - | - | - | - | Open Frame | 90 ~ 264 VAC | 50.8mm (2.00") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial), Medical | CE, cURus, FCC, TUV | - | - | - | 1.33A | - | 3.00" L x 2.00" W x 0.98" H (76.2mm x 50.8mm x 25.0mm) | 88% | Universal Input | - | - | - | - | - | - | - | - | - | Through Hole | - | 1 | -20°C ~ 70°C (With Derating) | 1.33A | - | 30V | - | 6-DIP Module | - | 40 W | - | - | 60601-1; 60950-1 | - | - | - | - | Open Frame | 90 ~ 264 VAC | - | |
|
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CB, CE, cULus, cURus | - | - | - | 583mA | - | - | 78% | Universal Input | - | 19.5mm (0.77") | - | 47-440 Hz | - | - | 50.8mm (2.00") | - | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | 12 VDC | - | 4-DIP Module | - | 7 W | - | - | - | - | - | - | - | Enclosed | 85 ~ 264 VAC | 25.4mm (1.00") | |
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Household Appliances, ITE (Commercial), Medical | CE | - | - | - | 1.25A | - | - | 90% | Adjustable Output, Universal Input | - | 21.7mm (0.85") | - | - | - | - | 76.2mm (3.00") | - | - | Through Hole | - | 1 | -20°C ~ 70°C (With Derating) | - | - | 24V | - | 6-DIP Module | - | 30 W | - | - | - | - | - | - | - | Open Frame | 85 ~ 265 VAC | 50.8mm (2.00") | |
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Household Appliances, ITE (Commercial), Medical | CE | - | - | - | 630mA | - | - | 90% | Adjustable Output, Universal Input | - | 21.7mm (0.85") | - | - | - | - | 76.2mm (3.00") | - | - | Through Hole | - | 1 | -20°C ~ 70°C (With Derating) | - | - | - | - | - | - | 30 W | Not Present | - | - | - | - | - | - | Open Frame | 85 ~ 265 VAC | 50.8mm (2.00") | |
XP Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | cUL, IEC, EN | - | - | - | 1 A | - | - | 69% | Universal Input | - | 23.0mm (0.91") | - | - | - | 3000 VAC | 58.5mm (2.30") | - | - | Through Hole | - | 1 | 0°C ~ 70°C | - | - | - | 120-180% | 5-DIP Module | - | 5 W | - | - | 62368-1 | -20°C ~ 80°C | - | 0.2 %/˚C | - | Open Frame | 90 ~ 264 VAC | 35.5mm (1.40") | |
|
Morning Star Industrial
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Household Appliances, ITE (Commercial) | - | - | - | - | 6.7A | - | - | 92% | - | - | - | - | 47 - 63 Hz | - | - | - | - | - | Through Hole | < 0.21W | 1 | -40°C ~ 85°C (With Derating) | - | - | - | - | 4-DIP Module | - | 80.4W | - | - | 60335-1; 62368-1 | - | - | ±0.02%/℃ | - | Enclosed | 80 - 305 VAC | - | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus, EN, UL | - | - | - | 1.1A | - | - | 76% | Universal Input | - | - | - | - | - | - | - | - | - | Through Hole | - | 1 | [{'min': -25, 'max': 70, 'unit': '°C', 'display_value': '-25°C ~ 70°C (With Derating)'}] | - | - | 9VDC | - | - | - | 10 W | - | - | 60950-1 | - | - | - | - | Enclosed | [{'min': 85, 'max': 264, 'unit': 'VAC', 'display_value': '85 ~ 264 VAC'}] | - | |
XP Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CSA, cUL, EN, UL | - | - | - | 410mA | - | - | 82 % | Universal Input | - | 15.2mm (0.60") | - | - | - | - | 25.4mm (1.00") | - | - | Through Hole | - | 1 | -25°C / 70°C | - | 5 W | - | - | - | - | 5 W | - | - | 62368-1 | - | - | - | - | Enclosed | 85 ~ 264 VAC, 120 ~ 370 VDC | 25.4mm (1.00") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Household Appliances, ITE (Commercial) | CE, cURus, FCC | - | - | - | 5.8A | - | - | 90% | Universal Input | - | 29.0mm (1.14") | - | - | - | - | 76.2mm (3.00") | - | - | Through Hole | - | 1 | -30°C ~ 80°C (With Derating) | - | - | 12V | - | - | - | 70 W | - | - | 60335-1; 62368-1 | - | - | - | - | Open Frame | 90 ~ 264 VAC, 120 ~ 370 VDC | 50.8mm (2.00") | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CB Scheme, EN, IEC, SIQ, TUV, UL | - | - | - | 2 A | 65 x 45 x 18.5 mm (2.56 x 1.77 x 0.73 inches) | - | 75 % | Universal Input | 47 ~ 63 Hz | 23.1mm (0.91") | - | - | - | - | 65.0mm (2.56") | - | - | Through Hole | 0.5 W | 1 | 0 ~ 60 °C | - | - | - | - | - | - | 10 W | - | - | 55024; 60950-1; 61000-3-2; 61000-3-3 | -20 ~ 85 °C | - | ±0.05 %/°C | - | Open Frame | 5 VDC | 45.0mm (1.77") | |
XP Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial), Medical | cUL, IEC, EN | - | - | - | 630mA | - | - | 84% | Universal Input | - | 28.2mm (1.11") | - | 47-63 Hz | 90-264 VAC | 4000 VAC | 69.0mm (2.72") | - | - | Through Hole | - | 1 | 0°C ~ 70°C (With Derating) | - | - | - | 120-280 % | - | - | 15 W | - | - | 60601-1; 60950-1; 62368-1 | -20°C to +80°C | - | 0.2 %/°C | - | Enclosed | 24 V | 42.0mm (1.65") | |
XP Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial), Medical | cUL, IEC, EN | - | - | - | 2.00 A | - | - | 74% | Universal Input | - | - | - | 47-63 Hz | 90-264 VAC | 4000 VAC | - | - | - | Through Hole | - | 1 | 0 °C to +70 °C, derate from 100% load at 50 °C to 50% load at 70 °C | - | - | - | 120-280 %, auto recovery | 5-DIP Module | - | 15 W | - | - | 60601-1; 60950-1; 62368-1 | -20 °C to +80 °C | - | 0.2 %/°C | - | Enclosed | 5.0 V | - | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CB, CE, cURus | - | - | - | 1.67A | - | - | 84% | Universal Input | - | - | - | - | - | - | - | - | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | - | - | 20 W | - | - | - | - | - | - | - | Enclosed | 90 ~ 264 VAC, 100 ~ 375 VDC | - | |
TT Electronics/BI
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial), Medical | CB, CE, cURus | - | - | - | 5A | - | - | 84% | Universal Input | - | 23.5mm (0.93") | Yes | - | - | - | 64.1mm (2.52") | Yes | - | Through Hole | - | 1 | -40°C ~ 80°C (With Derating) | - | - | - | - | 5-DIP Module, 4 Leads | - | 25 W | Not Present | - | 60601-1; 60950-1 | - | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | 45.6mm (1.80") | |
|
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, EN, IEC, UL | - | - | - | 1.25A | - | - | 81% | Universal Input | - | 23.5mm (0.93") | - | - | - | - | 64.0mm (2.52") | Yes | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | - | - | 15W | - | - | 60601-1; 60950-1; 62368-1 | - | - | - | - | Enclosed | 90 ~ 264 VAC, 100 ~ 375 VDC | 45.6mm (1.80") | |
TDK Corporation
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, CSA, TUV, UL | - | - | - | 520mA, 520mA | - | - | 73% | Universal Input | - | 23.5mm (0.93") | - | 47-440 Hz | - | - | 70.0mm (2.75") | - | - | Through Hole | - | 2 | -10°C ~ 70°C (With Derating) | - | - | - | - | 6-DIP Module | - | 15 W | - | - | - | - | - | - | - | Enclosed | -15 VDC | 48.0mm (1.89") | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, cURus, UKCA | - | - | - | 8.33 A | - | - | 90 % | EN 60601 3.1 certified, 4,000 Vac isolation, 2 MOPP, adjustable output voltage, power factor > 90%, Class I or Class II | 47 ~ 63 Hz | 35.0mm (1.38") | - | - | - | - | 83.9mm (3.30") | Yes | - | Through Hole | 0.3 W | 1 | -30°C ~ 70°C | - | - | 12 Vdc | - | - | - | 100 W | - | - | 60601-1 | -30°C ~ 85°C | - | ±0.05 %/°C | - | Enclosed | 90 ~ 264 Vac | 58.5mm (2.30") | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, cURus, UKCA | - | - | - | 2.08A | - | - | 90% | Adjustable Output, PFC, Remote On/Off, Universal Input | 47 ~ 63 Hz | 35.0mm (1.38") | - | - | - | - | 83.9mm (3.30") | Yes | - | Through Hole | 0.3 W | 1 | -30°C ~ 70°C (With Derating) | - | - | 48 Vdc | - | 7-DIP Module | - | 100 W | - | - | 60601-1 | -30 ~ 85 °C | - | ±0.05 %/°C | - | Enclosed | 90 ~ 264 Vac | 58.5mm (2.30") | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, cURus, UKCA | - | - | - | 4.16A | - | - | 90% | Adjustable Output, PFC, Remote On/Off, Universal Input | - | - | - | - | - | - | - | - | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | - | - | 100 W | - | 3.30" L x 2.30" W x 1.38" H (83.9mm x 58.5mm x 35.0mm) | 60601-1 | - | - | - | - | Enclosed | 90 ~ 264 VAC | - | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | Medical | CE, cURus, UKCA | - | - | - | 12.5A | - | - | 93% | Adjustable Output, PFC, Remote On/Off, Universal Input | 47 ~ 63 Hz | 35.0mm (1.38") | - | - | - | - | 109.0mm (4.29") | - | - | Through Hole | 0.5 W | 1 | -30°C ~ 70°C (With Derating) | 12.50 A | 150 W | 12 Vdc | - | 7-DIP Module | - | 150 W | - | - | 60601-1 | -30 ~ 85 °C | - | ±0.05 %/°C | - | Enclosed | 90 ~ 264 VAC | 58.5mm (2.30") | |
Cincon Electronics Co. LTD
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, cURus, DEMKO | - | Class I | CE101/CE102/RE101 of MIL-STD-461 | 58.4A | - | - | 87.5% | Adjustable Output, Baseplate, PFC, Remote On/Off, Universal Input | - | 12.7mm (0.50") | - | - | - | - | 116.8mm (4.60") | - | - | Through Hole | - | 1 | -40°C ~ 100°C (With Derating) | 58.4 A | - | 12 Vdc | - | - | - | 701 W | - | - | 62368-1 | - | - | - | - | Enclosed | 90 ~ 264 VAC | 61.0mm (2.40") | |
|
Artesyn Embedded Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | ITE (Commercial) | CE, CSA, UL | - | - | - | 6A | - | - | 97% | Adjustable Output, Baseplate, Load Sharing, PFC, PMBus™, Remote On/Off, Universal Input | - | 14.0mm (0.55") | - | - | - | - | 116.8mm (4.60") | - | - | Through Hole | - | 1 | -40°C ~ 100°C | - | - | - | - | - | - | 2.4 kW | - | - | 62368-1 | - | - | - | - | Enclosed | 85 ~ 264 VAC | 61.0mm (2.40") |
Showing 6051-6100 of 6,610 products