| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Breaker Type | |
| Current Rating (Amps) | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. 4430.2525 is a 2-pole thermal circuit breaker for equipment protection, offering a rated voltage of 240 VAC and 60 VDC. It features a rocker actuation and a panel mount design, making it suitable for various industrial applications.
This circuit breaker provides thermal overload protection with a rated current range of 0.05 to 20 A AC. It has a mechanical lifetime of 50,000 switching cycles and an operating temperature range of -10 °C to 55 °C. The device meets IP40 degree of protection on the front side.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment. Its robust design and thermal tripping mechanism ensure reliable protection against overcurrent conditions.
The breaker is rated for 240 VAC and 60 VDC.
The rated current is 10 A.
The operating and storage temperature range is -10 °C to 55 °C.
It is a panel-mount breaker with rocker actuation.
The front side is IP40, or IP54 with a factory-mounted protection cover.
It is rated for 50,000 mechanical switching cycles and 50,000 electrical switching cycles at 1 x Ir for AC and DC loads.
Conditional short-circuit capacity is 1 kA at 240 VAC. Icn is 10xIn below 3 A at 240 VAC/60 VDC, 300 A at or above 3 A at 240 VAC, and 120 A at or above 3 A at 48 VDC.