| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Failure Rate | |
| Features | |
| Frequency | |
| Height | |
| Industrial Grade | |
| Input Voltage | |
| Isolation | |
| Length | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| SVHC Present | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP8-2Q-2Q-1L-00 is a high-power AC DC converter with a rating of 1000W. Designed for versatility, it supports a wide input voltage range of 85-264 VAC and 120-350 VDC, operating at frequencies from 47-440 Hz. This enclosed converter features a chassis mount type and offers adjustable output, power factor correction (PFC), and remote On/Off functionality.
With three outputs, this model is suitable for applications requiring multiple voltage rails. It boasts an efficiency of up to 85% and operates within a temperature range of -40°C to 70°C with derating. Key features include overload protection, voltage adjustment on all outputs, and a 2-year warranty. The unit complies with various safety standards including UL1950, CSA22.2 No. 234, IEC950, and EN60950, and carries CE Mark approval.
Designed for demanding environments, the MP8-2Q-2Q-1L-00 includes features like current share on outputs rated 10A or greater, remote sense on outputs greater than 2A, and an input OK signal. It also offers options for low leakage current, making it suitable for medical applications. The cooling system utilizes an internal DC fan or customer-provided air, with a field-replaceable fan and fan fail signal for reliability.
85-264 VAC or 120-350 VDC.
The operating temperature range is -20°C to 50°C standard, with derating to -40°C to 70°C. Note that start-up is at 0°C.
Three outputs: 2x24V and 12V, total power 1000W.
Yes, typical power factor of 0.99 and meets EN61000-3-2 harmonic standards.
UL1950, CSA22.2 No. 234, IEC950, EN60950, CE mark.
Yes, all outputs have ±10% minimum adjustment range.
Internal DC fan (field-replaceable) or customer-provided air.