The Artesyn Embedded Power MP8-2L-2L-1F-4QQ-00 is a versatile AC DC converter designed for demanding applications. This enclosed unit delivers up to 1000W of power and accepts a wide input voltage range of 85-264 VAC, with a typical efficiency of 70-80% and a power factor of 0.99.
Featuring five outputs, including adjustable voltage and margining capabilities, this converter is suitable for ITE (Commercial) and Medical applications. It offers robust protection features such as overload protection and remote sense on outputs rated over 2A. The unit is designed for chassis mounting and includes features like power factor correction and remote on/off control.
Operating within a temperature range of -20°C to 50°C (with derating to 70°C), the MP8 series is built to withstand challenging environments, meeting Mil-Hdbk 810E for shock and vibration. Compliance with major safety standards including UL, CSA, IEC, VDE, and CE Mark ensures reliability and broad applicability.
Additional features include an input OK signal, global DC OK signal, and individual module inhibits/enable, providing comprehensive system monitoring and control. The power factor correction meets EN61000-3-2 harmonic distortion compliance, and it offers both standard and low leakage options for conducted/radiated EMI.
The input voltage range is 85-264 VAC or 120-350 VDC at 47-440 Hz.
The operating temperature range is -20°C to 50°C, with linear derating to 50% output at 70°C.
It carries UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, VDE EN60950, BABT, CB certificate, and CE Mark approvals.
The MP8-2L-2L-1F-4QQ-00 provides five outputs: two 12V rails, one 5.2V rail, and three 24V rails, totaling 1000W.
Yes, it has power factor correction with a typical power factor of 0.99, meeting EN61000-3-2 harmonic distortion requirements.
The holdover storage time is 20 ms minimum, independent of input VAC.
Leakage current is 2.0 mA max at 240 VAC standard, with a 300 µA max low-leakage option for medical applications.