| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Failure Rate | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-2Q-1L-4LE-00 is a versatile 800W AC/DC converter from the MP Series, suitable for ITE (Commercial) and Medical applications. This enclosed unit is designed for chassis mounting and offers a universal input voltage range of 85-264 VAC.
Key electrical specifications include a power output of 800W, a current rating of 10A, and multiple outputs including 5V. The converter boasts an efficiency of up to 85% and features power factor correction, meeting EN61000-3-2 standards. Special features enhance its utility, such as current sharing on higher-rated outputs, remote sense capabilities, overload protection, and adjustable voltage on all outputs. It also includes an Input OK signal and status indicator LED, as well as global and individual module inhibits/enable functions.
The operating temperature range is -40°C to 70°C with derating, and it meets stringent environmental and safety standards including UL1950, CSA, IEC, and VDE. The unit supports forced air cooling with a field-replaceable fan and complies with CISPR 22 and EN55022 Class B for conducted and radiated EMI. A low leakage option is available for medical applications.
The input voltage range is 85-264 VAC or 120-350 VDC at 47-440 Hz.
The converter provides four outputs: 24V, 2x12V, and 5V, with a total power of 800W.
The operating temperature range is -20°C to 50°C (start at 0°C), with derating available to -40°C to 70°C.
The converter has UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, and CE Mark approvals, with CB certificate and report.
Yes, it has a typical power factor of 0.99 and meets EN61000-3-2 harmonic distortion requirements.
The holdover storage time is 20 ms minimum, independent of input VAC.
It uses forced air cooling with an internal DC fan or customer-provided air option, and includes a low-noise field-replaceable fan with fan fail signal.