The Artesyn Embedded Technologies MP6-2D-1E-1L-4LE-00 is a high-power AC DC converter designed for demanding applications. This enclosed unit offers a total power output of 800W and features a 5V output with a current rating of 10A, alongside four other outputs.
Key electrical specifications include a wide input voltage range of 85-264 VAC and an efficiency of up to 85%. The converter supports features such as adjustable output, power factor correction (PFC), and remote on/off control, making it versatile for various system designs. It meets EN61000-3-2 harmonic distortion compliance and CISPR 22, EN55022 Class B conducted and radiated EMI standards.
Designed for reliability, the MP6-2D-1E-1L-4LE-00 operates within a temperature range of -40°C to 70°C with derating. Its chassis mount type and enclosed form factor facilitate integration into industrial and medical equipment. Safety approvals include CB, CE, CSA, UL, and VDE, ensuring compliance with international standards.
This power supply is suitable for ITE (Commercial) and Medical applications, benefiting from features like overload protection and remote sense capabilities on outputs rated above 2A. The unit also includes global inhibit/enable functions and status indicator LEDs for system monitoring.
85-264 VAC or 120-350 VDC, 47-440 Hz.
UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, BABT EN 60950, CE Mark, and CB Certificate.
-20°C to 50°C (start at 0°C) or -20°C to 40°C with rear air option. With derating, -40°C to 70°C is possible.
70-80% typical at full case load, with a peak efficiency of 85% possible.
Yes, it has power factor correction with a typical power factor of 0.99 and meets EN61000-3-2 harmonic distortion standards.
Enclosed chassis mount with forced air cooling using an internal DC fan.
Five outputs, configurable as 3.3V, 5V, 2x12V, and 2x5V, all adjustable with remote sensing and current sharing on outputs above 10A.