AC DC Converters are electronic devices that convert alternating current (AC) into direct current (DC), enabling the operation of DC-powered devices. They are widely used in applications such as industrial power management, power conversion subsystems, and maintenance and field replacement. Important specifications for selection include Efficiency, which impacts energy consumption; Current, which determines the load capacity; and Operating Temperature, which ensures reliability under varying environmental conditions. Procurement teams should validate lifecycle status and consider alternate-source options to mitigate sourcing risks.
Parts in this category
Tap rows to select parts
Compare stocked parts across manufacturers and distributors, then add lines to your RFQ.
| Part & Mfr | Applications | Approval Agency | Automotive Grade | Current | Duration | Efficiency | Failure Rate | Features | Frequency | Height | Industrial Grade | Input Frequency | Input Voltage | Length | Medical Grade | Military Grade | Mounting Type | No Load Power Consumption | Number of Outputs | Operating Temperature | Output Current | Output Power | Output Voltage | Overload Protection | Package / Case | Power (Watts) | Power Consumption | Power Rating | SVHC Present | Standard Number | Storage Temperature | Tape & Reel | Temperature Coefficient | Type | Voltage | Weight | Width | Working Voltage | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Aimtec
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus | - | 1.66A | - | 84% | - | Universal Input | - | 25.0mm (0.98") | - | - | 85-264 VAC | 89.0mm (3.50") | - | - | Through Hole | - | 2 | -40°C ~ 70°C (With Derating) | - | - | - | - | 7-DIP Module, 5 Leads | 40 W | - | - | - | - | - | - | - | Enclosed | -12V | - | 63.5mm (2.50") | - | |
Aimtec
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus | - | 1.33A, 1.33A | - | 84% | - | Universal Input | - | 25.0mm (0.98") | - | - | - | 89.0mm (3.50") | - | - | Through Hole | - | 2 | -40 °C to +70 °C | 1.33A | - | ±15V | - | - | 40 W | - | - | - | - | - | - | - | Enclosed | -15V | - | 63.5mm (2.50") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, CSA, UL | - | 8A | - | 85% (typ) @ 115VAC | - | Universal Input | - | 28.7mm (1.13") | Yes | 47 ~ 63 Hz | 90 ~ 264 VAC | 76.2mm (3.00") | Yes | - | Through Hole | - | 1 | -20°C ~ 70°C (With Derating) | - | - | - | - | - | 40W | - | - | Not Present | 60950-1 | - | - | - | Open Frame | 5V | - | 50.8mm (2.00") | - | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, CSA, cURus, UKCA | - | 1.81A | - | 93% | - | DC Input Capable, Universal Input | - | 30.5mm (1.20") | - | 47 - 63 Hz | - | 81.3mm (3.20") | - | - | Through Hole | - | 1 | –40°C to 80°C | - | - | 36 VDC | - | - | 65 W | 210 mW | - | - | 60601-1; 62368-1 | - | - | - | Enclosed | 85 ~ 264 VAC, 100 ~ 240 VAC, 120 ~ 370 VDC | - | 55.9mm (2.20") | 250 VAC | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, CSA, cURus, UKCA | - | 10A | - | 90% | - | DC Input Capable, Universal Input | - | 30.5mm (1.20") | - | 47 - 63 Hz | - | 81.3mm (3.20") | - | - | Through Hole | - | 1 | -40°C to 80°C | - | - | 4.5 - 5.5 VDC | - | 6-DIP Module, 5 Leads | 50 W | 210 mW | - | - | ES 60601-1 | - | - | - | Enclosed | 100 - 240 VAC | - | 55.9mm (2.20") | 250 VAC | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CB, CE, cULus, cURus | - | 4A | - | 83% | - | Universal Input; Over-temperature protection; Protection against short circuit and overload | - | 34.2mm (1.35") | - | 47-440 Hz | - | 88.9mm (3.50") | - | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | 15 VDC | - | 6-DIP Module, 4 Leads | 60 W | - | - | - | - | - | - | - | Enclosed | 85 ~ 264 VAC | - | 67.5mm (2.66") | - | |
|
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cULus | - | 4A | - | 79% | - | Universal Input | - | 22.3mm (0.88") | - | - | - | 70.0mm (2.76") | - | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | 8-DIP Module, 5 Leads | 20 W | - | - | - | 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 48.0mm (1.89") | - | |
|
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cULus | - | 1.67A | - | 83% | - | Universal Input | - | 22.3mm (0.88") | - | - | - | 70.0mm (2.76") | - | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | 12V | - | - | 20 W | - | - | - | 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 48.0mm (1.89") | - | |
|
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cULus | - | 840mA | - | 84% | - | Universal Input | - | 22.3mm (0.88") | - | - | - | 70.0mm (2.76") | - | - | Through Hole | - | 1 | -25°C ~ 70°C (With Derating) | - | - | - | - | 8-DIP Module, 5 Leads | 20 W | - | - | - | 60950-1 | - | - | - | Enclosed | 24 VDC | - | 48.0mm (1.89") | - | |
|
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CB, CE, cURus | - | 8A | - | 84% | - | Universal Input | - | 25.0mm (0.98") | Yes | - | - | 89.5mm (3.52") | - | - | Through Hole | - | 1 | -40°C ~ 60°C (With Derating) | - | - | - | - | - | 40 W | - | - | - | - | - | - | - | Enclosed | 90-264 VAC, 100-375 VDC | - | 64.1mm (2.52") | - | |
Aimtec
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus | - | 2.5 A | - | 86 % | - | Adjustable Output, Universal Input | - | 30.0mm (1.18") | - | - | - | 109.0mm (4.29") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | - | 60 W | - | - | - | - | -40°C ~ +85°C | - | ±0.02 % / °C | Enclosed | 24 V | 310 g | 58.5mm (2.30") | - | |
Mean Well USA
|
Send RFQ |
Price on request
Price and Stock
on Request |
Medical | CB, CE, cURus, TUV | - | 2.5A | - | 66% | - | Universal Input | - | 22.7mm (0.89") | - | - | - | 70.0mm (2.76") | - | - | Through Hole | - | 1 | -20°C ~ 70°C (With Derating) | - | - | - | - | 4-DIP Module | 8 W | - | 8.25W | Not Present | - | - | - | - | Enclosed | 3.3V | 0.23 lb | 50.0mm (1.97") | - | |
Aimtec
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus | - | 5A | - | 86% | - | Adjustable Output, Universal Input | - | 30.0mm (1.18") | - | - | - | 109.0mm (4.29") | - | - | Through Hole | - | 1 | -40°C ~ 70°C | - | - | 12V | - | 6-DIP Module | 60W | - | - | - | - | -40°C ~ 85°C | - | ±0.02%/°C | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus, UKCA | No | 5.83A | - | 88% | - | Adjustable Output, Universal Input | 47 ~ 63 Hz | 17.0mm (0.67") | Yes | - | - | 61.0mm (2.40") | - | No | Through Hole | 150 mW | 1 | -40°C ~ 85°C (With Derating) | - | - | - | - | Half Brick | 70 W | - | - | - | 62368-1 | - | - | - | Enclosed | 12 Vdc | - | 57.9mm (2.28") | - | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus, UKCA | - | 1.46A | - | 89.5% | - | Adjustable Output, Universal Input | 47 ~ 63 Hz | - | - | - | - | - | - | - | Through Hole | 0.15 W | 1 | -40°C ~ 85°C (With Derating) | - | - | 48 Vdc | - | Half Brick | 70 W | - | - | - | 62368-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | - | - | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus | - | 8A | - | 86% | - | Universal Input | - | 21.8mm (0.86") | - | - | - | 74.1mm (2.92") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | - | 40 W | - | - | - | - | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | - | 54.1mm (2.13") | - | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | - | - | 3.333A | - | 87% | - | Universal Input | - | 21.8mm (0.86") | - | - | - | 74.1mm (2.92") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | 4-DIP Module | 50W | - | - | - | - | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | - | 54.1mm (2.13") | - | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus | - | 1.04A | - | 89% | - | Universal Input | - | 21.8mm (0.86") | - | - | - | 74.1mm (2.92") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | - | - | - | 50 W | - | - | - | - | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | - | 54.1mm (2.13") | - | |
|
Aimtec
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, cURus | - | 420mA | - | 79% | - | Universal Input | - | 25.1mm (0.99") | - | - | - | 56.5mm (2.22") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | 24V | - | 5-DIP Module, 4 Leads | 10 W | - | - | - | - | - | - | - | Enclosed | 90 ~ 264 VAC | - | 30.9mm (1.21") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 2.5A | - | 87% | - | Universal Input | - | 27.0mm (1.06") | - | - | - | 89.0mm (3.50") | Yes | - | Through Hole | - | 1 | -40°C ~ 80°C (With Derating) | - | - | - | - | - | 60 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | - | 63.5mm (2.50") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 5A | - | 88% | - | Universal Input | - | 27.0mm (1.06") | - | - | - | 89.0mm (3.50") | - | - | Through Hole | - | 1 | -40°C ~ 80°C (With Derating) | - | - | - | - | 7-DIP Module, 4 Leads | 60 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | - | 63.5mm (2.50") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 10A | - | 86% | - | Universal Input | - | 27.0mm (1.06") | Yes | - | - | 89.0mm (3.50") | Yes | - | Through Hole | - | 1 | -40°C ~ 80°C (With Derating) | - | - | - | - | 7-DIP Module, 4 Leads | 50 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | - | 63.5mm (2.50") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 4A | - | 86% | - | Universal Input | - | 27.0mm (1.06") | - | - | - | 89.0mm (3.50") | - | - | Through Hole | - | 1 | -40°C ~ 80°C (With Derating) | - | - | - | - | - | 60 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC, 120 ~ 370 VDC | - | 63.5mm (2.50") | - | |
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE | - | 1.67A | - | 83% | - | Universal Input | - | - | - | - | - | - | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | 24 VDC | - | 7-DIP Module, 5 Leads | 40 W | - | - | - | 60950-1 | - | No | - | Enclosed | 90-264 VAC | - | - | - | |
|
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CB, CE, cURus | - | 4A | - | 84% | - | Universal Input | - | 25.0mm (0.98") | - | - | - | 89.5mm (3.52") | - | - | Through Hole | - | 2 | -40°C ~ 60°C (With Derating) | - | - | - | - | - | 40W | - | - | - | - | - | - | - | Enclosed | -5V | - | 64.1mm (2.52") | - | |
|
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CB, CE, cURus | - | 1.666A, 1.666A | - | 84% | - | Universal Input | - | 25.0mm (0.98") | - | - | - | 89.5mm (3.52") | - | - | Through Hole | - | 2 | -40°C ~ 60°C (With Derating) | - | - | - | - | - | 40 W | - | - | - | - | - | - | - | Enclosed | -12V | - | 64.1mm (2.52") | - | |
CUI Inc.
|
Send RFQ |
Price on request
Price and Stock
on Request |
Household Appliances, ITE (Commercial) | CE, cURus | - | 420mA | - | 83% | - | - | 47 Hz / 63 Hz | - | - | - | - | - | - | - | Through Hole | 0.15 W | 1 | -40°C ~ 85°C / 85°C | 0.42 A | 10 W | - | - | - | 10 W | - | - | - | 60335-1; 62368-1 | - | - | ±0.02 %/°C | Open Frame | 24 Vdc | - | - | - | |
|
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CB, CE, cURus | - | 5A, 1.25A | - | 84% | - | Universal Input | - | - | - | - | - | - | - | - | Through Hole | - | 2 | -40°C ~ 60°C (With Derating) | - | - | - | - | 8-DIP Module, 6 Leads | 40 W | - | - | Present | - | - | - | - | Enclosed | 12V | - | - | - | |
|
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CB, CE, cURus | No | 5A, 625mA | - | 84% | - | Universal Input | - | 25.0mm (0.98") | No | - | - | 89.5mm (3.52") | No | No | Through Hole | - | 2 | -40°C ~ 60°C (With Derating) | - | - | - | - | 8-DIP Module, 6 Leads | 40 W | - | - | - | - | - | - | - | Enclosed | 24V | - | 64.1mm (2.52") | - | |
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
Industrial, ITE (Commercial), Medical | CB, CE, cULus, cURus | - | 4A | - | 87% | - | Universal Input | - | - | - | - | - | - | - | - | Through Hole | <0.3 W | 1 | -40°C ~ 75°C (With Derating) | 4 A | - | 15 VDC | - | - | 60 W | - | - | Not Present | - | - | - | - | Enclosed | 85 ~ 264 VAC, 120 ~ 370 VDC | - | - | - | |
Aimtec
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, cURus | - | 840mA | - | 79% | - | Universal Input | - | 25.1mm (0.99") | - | - | - | 56.5mm (2.22") | - | - | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | 24V | - | 5-DIP Module, 4 Leads | 20 W | - | - | - | - | - | - | - | Enclosed | 90 ~ 264 VAC, 130 ~ 370 VDC | - | 30.9mm (1.21") | - | |
Aimtec
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, cURus | - | 1.33A | - | 81% | - | Universal Input | - | - | No | - | - | - | Yes | No | Through Hole | - | 1 | -40°C ~ 70°C (With Derating) | - | - | 15V | Yes | 5-DIP Module, 4 Leads | 20 W | - | - | Present | - | - | - | - | Enclosed | 130-370 VDC | - | - | - | |
|
Traco Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CB, CE, cURus | - | 5A, 600mA, 600mA | - | 84% | - | Universal Input | - | 25.0mm (0.98") | - | - | - | 89.5mm (3.52") | - | - | Through Hole | - | 3 | -40°C ~ 60°C (With Derating) | - | - | - | - | 8-DIP Module, 7 Leads | 39 W | - | - | Present | - | - | - | - | Enclosed | -12V | - | 64.1mm (2.52") | - | |
Aimtec
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus | - | 5A, 625mA | - | 82% | - | Universal Input | - | 25.0mm (0.98") | - | - | - | 89.0mm (3.50") | - | - | Through Hole | - | 2 | -40°C ~ 70°C (With Derating) | 5/0.625 A | - | 5/24 V | - | - | 40 W | - | - | - | - | - | - | - | Enclosed | 24V | - | 63.5mm (2.50") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 4.167A | 3.30" L x 2.30" W x 1.38" H (83.9mm x 58.5mm x 35.0mm) | 90% | 100ACMEB (100W) | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | - | - | - | 83.9mm (3.30") | Yes | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | 7-DIP Module | 100 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 6.666A | - | 90% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | Yes | - | - | 83.9mm (3.30") | Yes | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | - | 80 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 2.083A | - | 90% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | Yes | 47-63 Hz | 90-264 VAC | 83.9mm (3.30") | Yes | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | 2.083A | - | 48V | - | 7-DIP Module | 100 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CE, UL | - | 15A | - | 87% | - | Adjustable Output, Universal Input | - | 30.0mm (1.18") | - | - | - | 127.0mm (5.00") | - | - | Chassis Mount | - | 1 | 0°C ~ 60°C (With Derating) | - | - | - | - | - | 120W | - | - | - | 60601-1; 60950-1 | - | - | - | Open Frame | 90 ~ 264 VAC | - | 76.2mm (3.00") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CE, UL | - | 7.5A | - | 87% | - | Adjustable Output, Universal Input | - | 30.0mm (1.18") | - | - | - | 127.0mm (5.00") | Yes | - | Chassis Mount | - | 1 | 0°C ~ 60°C (With Derating) | - | - | - | - | Module | 180W | - | - | - | 60601-1; 60950-1 | - | - | - | Open Frame | 90 ~ 264 VAC | - | 76.2mm (3.00") | - | |
|
Recom Power
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE | - | 1.33 A | - | 83% | - | Universal Input | - | 27.0mm (1.06") | - | - | - | 89.0mm (3.50") | - | - | Through Hole | - | 2 | -40°C ~ 70°C | - | - | - | - | 7-DIP Module, 5 Leads | 40 W | - | - | - | 60950-1 | - | No | - | Enclosed | -15 VDC | - | 63.5mm (2.50") | - | |
|
Polytron
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial) | CE, cURus, UL | - | 50mA | - | - | - | SCP | - | 25.4mm (1.00") | - | - | - | 57.2mm (2.25") | - | - | Through Hole | - | 1 | -25°C ~ 71°C / -40 to +85°C Optional | - | - | 24 VDC | - | - | - | - | - | - | - | -25 to +85°C | - | ±0.02%/°C typ. | Enclosed | 105 ~ 125 VAC | - | 44.5mm (1.75") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 8.33A | - | 92.5% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | - | - | - | 109.0mm (4.29") | Yes | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | - | 100 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 2.1A | 109.0mm x 58.5mm x 35.0mm (4.29" L x 2.30" W x 1.38" H) | 93.5% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | yes | - | - | 109.0mm (4.29") | yes | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | 7-DIP Module | 101 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 6.667A | 4.29" L x 2.30" W x 1.38" H (109.0mm x 58.5mm x 35.0mm) | 92.5% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | - | - | 90 ~ 264 VAC | 109.0mm (4.29") | - | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | 6.667A | - | 15V | - | - | 100 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 4.2A | - | 93% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | - | - | - | - | - | - | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | - | 101 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | - | - | |
|
Analog Devices / Maxim Integrated
|
Send RFQ |
Price on request
Price and Stock
on Request |
- | - | - | 2A | - | - | - | - | - | 41.1mm (1.62") | - | - | - | 88.9mm (3.50") | - | - | - | - | 1 | -25°C ~ 71°C | - | - | - | - | - | 10 W | - | - | Not Present | - | - | - | - | - | 105 ~ 125 VAC | - | 63.5mm (2.50") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 6.25A | - | 93.5% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | Yes | - | - | 109.0mm (4.29") | Yes | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | - | 150 W | - | - | Not Present | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 3.125A | 109.0mm x 58.5mm x 35.0mm | 93.5% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | - | - | - | - | - | - | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | 3.125A | - | 48V | - | 7-DIP Module | 150 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | - | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 10A | - | 93% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | - | - | - | 109.0mm (4.29") | - | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | 7-DIP Module | 150 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - | |
|
GAPTEC Electronic
|
Send RFQ |
Price on request
Price and Stock
on Request |
ITE (Commercial), Medical | CB, CE, UL | - | 12.5A | - | 93% | - | Adjustable Output, PFC, Remote On/Off, Universal Input | - | 35.0mm (1.38") | - | - | - | 109.0mm (4.29") | Yes | - | Through Hole | - | 1 | -30°C ~ 70°C (With Derating) | - | - | - | - | - | 150 W | - | - | - | 60601-1; 60950-1 | - | - | - | Enclosed | 90 ~ 264 VAC | - | 58.5mm (2.30") | - |
Showing 4251-4300 of 6,610 products