| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating |
This Schurter Inc. TA45-ABFYR090C0-AZM12 is a 2-pole thermal circuit breaker from the TA45 series, suitable for equipment protection. It offers a rated current of 9A and a rated voltage of 240 VAC or 60 VDC.
The breaker features a rocker actuation type and a snap-in panel mount design for easy installation. It has a thermal tripping mechanism and provides overload protection with a minimum of 40 trips at 6 times the rated current for AC operation.
Key specifications include a conditional short circuit capacity of 1 kA at 240 VAC and a rated short circuit capacity of 300A at 240 VAC. The operating temperature range is -10°C to 55°C, and it has a mechanical lifetime of 50,000 switching cycles.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, construction equipment, and cleaning equipment. It meets various approval standards including CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 9A.
This is a 2-pole circuit breaker.
It uses a rocker actuation type.
The allowable operating temperature is -10°C to 55°C.