| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-ABFXR090C0-AZM10 is a thermal circuit breaker featuring a 2-pole configuration and a rocker actuation type. It is designed for panel mounting and utilizes a snap-in installation method.
The circuit breaker has a rated current of 9A and a rated voltage of 240 VAC, with a DC rating of 60 VDC. It offers a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity (Icn) of up to 300A under specific conditions. The device provides a degree of protection of IP40 on the front side, which can be increased to IP54 with a factory-mounted protection cover.
Key electrical specifications include a dielectric strength of 4 kVAC and an insulation resistance greater than 100 MΩ at 500 VDC. Mechanically, it boasts a lifetime of 50,000 switching cycles. The operating temperature range is from -10 °C to 55 °C, with a similar range for storage.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment. It is approved by CSA C22.2 No 235, IEC60934, GB17701, and UL1077.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage is 240 VAC and 60 VDC.
The current rating is 9A.
It features a rocker actuation type.
The allowable operating temperature is -10 °C to 55 °C.
The front side has an IP40 degree of protection, which can be IP54 with a protection cover.
It is approved by CSA C22.2 No 235, IEC60934, GB17701, and UL1077.