| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-ABFGS030C0-AZM02 is a 2-pole thermal circuit breaker from the TA45 series. It provides reliable thermal overload protection with a current rating of 3A and a voltage rating of 240 VAC.
The circuit breaker features a rocker actuation type and a panel mount, snap-in mounting style, making it suitable for easy integration into equipment. It is designed for industrial applications, offering a mechanical lifetime of 50,000 switching cycles.
Key specifications include a tripping type of thermal, a degree of protection of IP40 (or IP54 with a protection cover), and a dielectric strength of 4 kVAC. The operating temperature range is -10 °C to 55 °C.
Approvals include CSA C22.2 No 235, IEC60934, GB17701, and UL1077, indicating compliance with various safety standards for electronic equipment.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated voltage for AC is 240 VAC and for DC is 60 VDC.
The rated current range AC is 0.05 - 20 A, and the specific rating for this part is 3A.
It features a rocker actuation type.
This circuit breaker has 2 poles.
The allowable operation temperature is -10 °C to 55 °C.
Approval agencies include CSA C22.2 No 235, IEC60934, GB17701, and UL1077.