| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Operating Temperature | |
| Storage Temperature | |
| Voltage Rating | |
| Weight |
The Schurter Inc. TA45-ABFGP040C0-AZM14 is a 2-pole thermal circuit breaker from the TA45 series. It provides reliable thermal overload protection for various applications.
Key electrical specifications include a rated AC voltage of 240 VAC and a rated DC voltage of 60 VDC. The rated current range is from 0.05 to 20 A AC, with this specific unit rated at 4A. It features a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity (Icn) of 300A at 240 VAC for currents 3A and above.
Mechanical and environmental features include a rocker actuation type and a snap-in panel mount. The degree of protection is IP40 on the front side. The breaker has a mechanical lifetime of 50,000 switching cycles and an operating temperature range of -10 °C to 55 °C.
Applications for this type of circuit breaker include power tools, industrial appliances, power supplies, equipment for construction, and cleaning equipment.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The rated AC voltage is 240 VAC.
The rated DC voltage is 60 VDC.
The current rating is 4A.
This circuit breaker has 2 poles.
The allowable operation temperature is -10 °C to 55 °C.
The RoHS status is RoHS3 Compliant.
The Moisture Sensitivity Level is 1 Unlimited.