| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Breaker Type | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Insulation Resistance | |
| Mounting Type | |
| Number of Poles | |
| Storage Temperature | |
| Tape & Reel | |
| Voltage Rating | |
| Weight |
This Schurter Inc. TA45-2R series thermal circuit breaker, part number TA45-ABFBFJ28C0-AZM10, offers reliable thermal overload protection for 1 or 2 poles. It is designed for panel mounting with a convenient snap-in feature.
The circuit breaker has a rated voltage of 240 VAC and 60 VDC, with a current rating of 2.8A. It provides a conditional short circuit capacity of 1 kA at 240 VAC and a short circuit capacity of 300A at 240 VAC for currents 3A or greater. The actuation type is a rocker, and it features 2 poles.
Key specifications include a dielectric strength of 4 kVAC, insulation resistance greater than 100 MΩ at 500 VDC, and a mechanical lifetime of 50,000 switching cycles. The operating temperature range is -10 °C to 55 °C. The degree of protection on the front side is IP40.
Applications for this circuit breaker include power tools, industrial appliances, power supplies, and equipment for construction and cleaning. It is approved by CSA, IEC, GB, and UL standards.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The current rating is 2.8A.
The AC voltage rating is 240 VAC.
The DC voltage rating is 60 VDC.
It has 2 poles.
It uses a rocker actuator.
The allowable operation temperature is -10 °C to 55 °C.
The RoHS status is RoHS3 Compliant.