| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Input Voltage | |
| Isolation | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Tape & Reel | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP8-2N-2Q-2Q-40 is an enclosed AC/DC converter designed for ITE (Commercial) and Medical applications. It delivers a total power of 1000W with a 24V output and a current rating of 30A.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. The converter boasts high efficiency typically between 70-80% at full load and a power factor of 0.99, meeting EN61000-3-2 standards. It offers features such as adjustable output, remote On/Off control, and a universal input.
This unit is chassis mountable and has dimensions of 254.0mm x 177.8mm x 63.5mm. It operates within a temperature range of -40°C to 70°C with derating. The converter is approved by major agencies including CB, CE, CSA, UL, and VDE, ensuring compliance for various international markets.
Special features include current share on outputs rated 10A or greater, remote sense on outputs greater than 2A, overload protection, and voltage adjustment on all outputs. It also provides an Input OK signal and status indicator LED, as well as global and individual module inhibits/enables.
The input voltage range is 85-264 VAC or 120-350 VDC, with a frequency of 47-440 Hz.
The converter is enclosed and chassis mount.
The operating temperature range is -20°C to 50°C (start at 0°C) with linear derating to 50% at 70°C. With rear air option, maximum is -20°C to 40°C.
Typical efficiency is 70-80% at full load.
Yes, the power factor is 0.99 typical and meets EN61000-3-2 harmonic distortion standards.
It meets CISPR 22 EN55022 Level B for both conducted and radiated EMI.
The warranty period is 2 years.