| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Failure Rate | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP8-2E-1L-1Q-4LE-00 is an enclosed AC/DC converter with a power rating of 1000W. It features a universal input voltage range of 85-264 VAC and 120-350 VDC, operating at frequencies from 47-440 Hz. The converter boasts an efficiency of up to 85% and a power factor of 0.99 typical, meeting EN61000-3-2 standards.
This model provides multiple outputs, including 5V, 12V, and 24V, with specific current ratings for each. Key features include adjustable output, power factor correction (PFC), remote on/off functionality, and compliance with various safety agencies like CB, CE, CSA, UL, and VDE. The operating temperature range is -40°C to 70°C with derating.
Designed for chassis mounting, the MP8-2E-1L-1Q-4LE-00 has dimensions of 254.0mm x 177.8mm x 63.5mm. It is suitable for demanding ITE (Commercial) and Medical applications requiring reliable power conversion. Special features include overload protection and remote sense capabilities on certain outputs.
The input voltage range is 85-264 VAC (47-440 Hz) or 120-350 VDC.
Output 1: 5V at 60A; Output 2: 12V at 17A; Output 3: 12V at 10A; Output 4: 5V at 10A; Output 5: 12V at 1A; Output 6: 12V at 1A. Total power is 1000W.
The operating temperature range is -40°C to 70°C with derating. For standard operation, the range is -20°C to 50°C (start at 0°C). With rear air option, the maximum is -20°C to 40°C.
Yes, it has active power factor correction with a typical power factor of 0.99, meeting EN61000-3-2 harmonic distortion requirements.
It meets EN55022 Level B and CISPR 22 for conducted and radiated EMI.
Yes, all outputs have a minimum adjustment range of ±10%. Each output can be adjusted independently.