| Category | |
| Manufacturer Name | |
| AEC Qualified | |
| Applications | |
| Approval Agency | |
| Automotive Grade | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Industrial Grade | |
| Input Voltage | |
| Isolation | |
| Length | |
| Medical Grade | |
| Military Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP8-2D-2L-1E-1L-03 is a versatile 1000W AC/DC converter, suitable for both ITE (Commercial) and Medical applications. This enclosed unit features a chassis mount for easy integration into systems.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. It boasts an efficiency of up to 85% and includes power factor correction meeting EN61000-3-2 standards. The converter offers 4 outputs, with a primary output current of 17A and a voltage of 12V. It also supports features like adjustable output, remote sense on outputs greater than 2A, overload protection, and margining on single output modules.
Environmental and safety compliance is robust, with approvals from CB, CE, CSA, UL, and VDE. The operating temperature range is -40°C to 70°C with derating, and it meets Mil-Hdbk 810E for shock and vibration. Special features include input/output OK signals, global and individual module inhibits/enables, and a field-replaceable fan for forced air cooling. The unit also offers a low leakage option for medical applications and meets CISPR 22, EN55022 Class B conducted and radiated EMI standards.
The input voltage range is 85-264 VAC or 120-350 VDC, at 47-440 Hz.
The operating temperature range is -20°C to 50°C (start at 0°C) with linear derating to 50% load at 70°C, or -20°C to 40°C with rear-air option. Storage temperature is -40°C to +85°C.
The package type is enclosed, and the mounting method is chassis mount.
Typical efficiency is 70-80% at full load, with a power factor of 0.99 typ.
It meets CISPR 22 and EN55022 Level B for conducted and radiated EMI, with a low-leakage option (300 µA max.) for medical applications.
Yes, it includes overload protection on all outputs, remote sense on outputs over 2 A, current share on outputs over 10 A, and voltage adjustment (±10% min.).
Safety approvals include UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, and CE marking. CB certificate and report are available.