The Artesyn Embedded Power MP6-3W-LLE-00 is a versatile 800W AC/DC converter from the MP Series, designed for demanding ITE (Commercial) and Medical applications. This enclosed unit features a chassis mount for easy integration into systems.
Key electrical specifications include a universal input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. It offers up to 4 outputs, with a typical output voltage of 5V and a current rating of 2A. The power factor is typically 0.99, meeting EN61000-3-2 standards, and efficiency is rated at 85% at full load. Special features include adjustable outputs, power factor correction, remote on/off control, and overload protection.
Environmental and safety certifications include UL1950, CSA22.2 No. 234, IEC950, and EN60950, along with CE Mark compliance. The operating temperature range is -20°C to 50°C, with derating required at higher temperatures. The unit also supports a low leakage option for medical applications, with leakage current as low as 300 µA @ 240 VAC.
This converter is suitable for various industrial and medical equipment requiring a reliable and efficient power supply. Its robust design and comprehensive feature set make it a strong choice for system designers.
The input voltage range is 85-264 VAC or 120-350 VDC, with a frequency range of 47-440 Hz.
The converter provides four outputs: 48V, two 12V outputs, and a 5V output. The 5V output is rated at 2 A; full output configuration is specified in the datasheet.
The operating temperature range is -20°C to 50°C (start at 0°C) with forced air cooling. With the rear air option, the maximum is 40°C.
Yes, it includes active power factor correction with a typical power factor of 0.99 and meets EN61000-3-2 harmonic distortion requirements.
It is approved to UL1950, CSA22.2 No. 234 Level 5, IEC950, EN60950, and carries CE marking. It also has a CB certificate and report.
Yes, all outputs can be adjusted by ±10% minimum. Single output modules also support margining of ±4-6% nominal.
Typical efficiency is 85% at full load.