| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Industrial Grade | |
| Isolation | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| SVHC Present | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-3S-2O-00 is a high-power AC DC converter from the MP Series, delivering up to 800W of power. It features a single output voltage of 18V with a current rating of 19A. This enclosed, chassis mount converter is designed for universal input voltage ranges (85-264 VAC, 120-350 VDC) and offers an efficiency of up to 85% with power factor correction.
Key features include adjustable output voltage with a range of ±10% and margining capabilities on single output modules. It also provides overload protection, remote sense on outputs greater than 2A, and an input OK signal. The unit operates within a temperature range of -40°C to 70°C with derating and meets various safety and EMI standards including UL, CSA, CE, and EN61000.
Designed for applications in ITE (Commercial) and Medical fields, the MP6-3S-2O-00 supports global and individual module inhibits/enables. It utilizes forced air cooling with a field-replaceable fan and offers options for customer-provided air. The converter complies with EN61000-3-2 harmonic distortion and CISPR 22, EN55022 Curve B conducted/radiated EMI standards.
The input voltage range is 85-264 VAC or 120-350 VDC.
The converter has two outputs: 30V and 18V. The 18V output provides 19A. Total power is 800W.
The operating temperature range is -40°C to 70°C with derating. Full power is available from -20°C to 50°C.
It is certified to UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, VDE EN60950, and BABT compliance to EN60950/BS7002. It also carries CE marking.
Yes, it includes power factor correction with a typical power factor of 0.99 and meets EN61000-3-2 harmonic distortion standards.
The typical efficiency is 85%.
It uses forced air cooling via an internal DC fan, with a field-replaceable fan. A customer-provided air option is also available.