The Artesyn Embedded Power MP6-3N-01 is a high-power AC/DC converter designed for ITE (Commercial) and Medical applications. This enclosed unit offers a total power output of 800W, with dual 15V outputs, each capable of delivering 14A. It is designed for chassis mounting.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. The converter boasts an efficiency of 70-80% typical at full load and features power factor correction, meeting EN61000-3-2 standards. It includes features such as adjustable output voltage, remote on/off control, and a universal input capability.
Environmental and safety features include operation from -20°C to 50°C (derating at higher temperatures), compliance with Mil-Hdbk 810E for shock and vibration, and 95% non-condensing humidity resistance. It holds approvals from CB, CE, CSA, UL, and VDE, indicating its suitability for various international markets. The unit also supports a low leakage option for medical applications and meets CISPR 22, EN55022 Class B conducted and radiated EMI standards.
The input voltage range is 85-264VAC (47-440Hz) or 120-350VDC.
It provides two 15V outputs, each rated at 14A, for a total power of 800W.
The operating temperature range is -20°C to 50°C, with derating to 50% at 70°C. Storage temperature is -40°C to 85°C.
It uses forced air cooling via an internal DC fan, which is field-replaceable. An optional customer-provided air cooling is also available.
The converter is chassis mount.
Yes, it includes active power factor correction with a typical power factor of 0.99, meeting EN61000-3-2 harmonic distortion requirements.
Overload protection on all outputs, as well as remote sense on outputs >2A and current share on outputs ≥10A.