| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-3I-2U-00 is a versatile AC DC converter from the MP Series, designed for ITE (Commercial) and Medical applications. This enclosed unit offers a power output of 800W, with a primary output voltage of 36V and a current rating of 10A. It supports universal input voltage ranging from 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz.
Key features include adjustable output voltage with a minimum range of ±10%, power factor correction (typ. 0.99), and remote On/Off functionality. The converter also provides an Input OK signal and a Global DC OK signal, along with global and individual module inhibits/enable options. For thermal management, it utilizes internal DC fan cooling or can be used with customer-provided air, operating between -20°C to 50°C (derating applies above 40°C with rear air option).
This AC DC converter is chassis mountable and meets various safety and compliance standards including UL, CSA, CE, VDE, and CB. It is designed for reliability with features like overload protection and holdover storage of 20 ms minimum. The unit also offers options for low leakage current, making it suitable for medical applications.
The input voltage range is 85-264 VAC or 120-350 VDC.
The converter provides dual outputs: 8V and 36V, each rated at 10A, with total power of 800W.
The operating temperature range is -20°C to 50°C, with derating to 50% at 70°C.
It complies with UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, and BS 7002.
Yes, it features power factor correction with a typical power factor of 0.99, meeting EN61000-3-2.
The unit is chassis mount and enclosed.
Cooling is provided by an internal DC fan or customer-provided air (optional).