The Artesyn Embedded Power MP6-3E-1N-1N-00 is a high-power AC DC converter from the MP Series, delivering up to 800W. This enclosed unit is designed for chassis mounting and offers a universal input voltage range of 85-264 VAC.
Key electrical specifications include a typical efficiency of 85% and power factor correction meeting EN61000-3-2 standards. The converter provides multiple outputs, including 5V and 15V rails, with adjustable output voltage and margining capabilities. It also features remote on/off functionality and status indicator LEDs for input and DC OK signals.
Designed for demanding applications, the MP6-3E-1N-1N-00 is suitable for ITE (Commercial) and Medical environments. It complies with various safety standards including UL, CSA, CE, and VDE. The operating temperature range is -20°C to 50°C, with derating required at higher temperatures or when using specific cooling options.
Special features include overload protection on all outputs, remote sense on outputs rated over 2A, and an isolated 5V bias voltage. The unit also supports current sharing on outputs rated 10A or greater. A low leakage option is available for medical applications, meeting stringent requirements.
The input voltage range is 85-264 VAC or 120-350 VDC.
The operating temperature range is -20°C to 50°C (start at 0°C), with linear derating to 50% at 70°C. With the rear air option, maximum ambient is 40°C.
Typical efficiency is 70-80% at full load.
Safety approvals include UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, and CB certificate.
Yes, it has a global inhibit/enable function with TTL logic (Logic 1 and Logic 0).
Minimum hold-up time is 20 ms, independent of input voltage.
Cooling is provided by an internal DC fan or optional customer-provided air.