| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-2Y-1Q-00 is an enclosed AC/DC converter designed for ITE (Commercial) and Medical applications. It provides 800W of power with a 24V output and 8.5A current across two outputs.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. The converter boasts high efficiency, typically 85%, and features power factor correction meeting EN61000-3-2 standards. It offers features such as adjustable output voltage (±10% min.), margining (±4-6% nom.), remote on/off control, and a universal input capability.
Operating within a temperature range of -40°C to 70°C with derating, the MP6-2Y-1Q-00 utilizes chassis mount for installation. It complies with various safety and environmental standards including CB, CE, CSA, UL, and VDE. The unit also includes overload protection and a 2-year warranty.
Special features include current share on outputs rated 10A or greater, remote sense on outputs greater than 2A, and an input OK signal with a status indicator LED. It also offers a low leakage option for medical applications, meeting CISPR 22, EN55022 Curve B for conducted and radiated EMI.
The input voltage range is 85-264 VAC (47-440 Hz) or 120-350 VDC.
The converter provides dual outputs: 60V and 24V, with a total power of 800W.
The operating temperature range is -40°C to 70°C with derating, or -20°C to 50°C standard start at 0°C. With rear air option, maximum is 40°C.
The converter is chassis mount and enclosed.
Efficiency is 85% typical under full load.
Yes, it has a power factor of 0.99 typical and meets EN61000-3-2 harmonic distortion requirements.
Conducted and radiated EMI meet CISPR 22 and EN55022 Curve B.