The Artesyn Embedded Power MP6-2Q-4NN-0N is an enclosed AC DC converter with a power rating of 800W and three outputs. It is designed for chassis mounting and operates with a universal input voltage range of 85-264 VAC.
Key electrical specifications include an efficiency of 85% typical, a power factor of 0.99 typical meeting EN61000-3-2, and an inrush current of 40A peak max with soft start. The unit offers adjustable output voltage with a minimum range of ±10% and nominal margining of ±4-6%. It features standard CISPR 22 EMI filtering and an option for low leakage with CISPR 22 EN55022 Level “B” filtering.
Environmental considerations include an operating temperature range of -20°C to 50°C (derating linearly to 50% at 70°C) and storage temperatures from -40°C to +85°C. The converter meets Mil-Hdbk 810E for shock and vibration and 95% non-condensing humidity.
This converter is suitable for ITE (Commercial) and Medical applications, with approvals from CB, CE, CSA, UL, and VDE. It includes features such as remote sense on outputs greater than 2A, overload protection, and voltage adjustment on all outputs.
The MP6-2Q-4NN-0N has a power rating of 800W.
The MP6-2Q-4NN-0N has 3 outputs.
The typical efficiency of the MP6-2Q-4NN-0N is 70-80% at full case load, and 85% is also listed.
The operating temperature range is -20°C to 50°C, with derating to 50% at 70°C. It can operate up to 70°C with derating, and a maximum of -20°C to 40°C with a rear air option.
The approval agencies for the MP6-2Q-4NN-0N include CB, CE, CSA, UL, and VDE.
The MP6-2Q-4NN-0N uses chassis mount.
Yes, the MP6-2Q-4NN-0N has overload protection on all outputs.