The Artesyn Embedded Power MP6-2Q-1R-00 is a high-performance AC DC converter from the MP Series, delivering up to 800W of power. This enclosed unit features a 28V output voltage and a current rating of 6.7A, making it suitable for demanding applications.
Designed for versatility, it accepts a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. Key features include adjustable output, power factor correction (PFC) meeting EN61000-3-2 standards, and remote on/off control. The converter also offers overload protection on all outputs and remote sense capabilities for outputs greater than 2A.
With an efficiency typically between 70-80% and a power factor of 0.99, this model is designed for reliable operation. It operates within a temperature range of -40°C to 70°C with derating and meets various safety and EMI standards, including UL, CSA, CE, and VDE. The chassis mount type ensures easy integration into various systems.
This converter is specifically suited for ITE (Commercial) and Medical applications, with an optional low leakage configuration available for medical use. It also includes features like an Input OK signal, Global DC OK signal, and global/individual module inhibits/enables for enhanced system monitoring and control.
The AC input voltage range is 85-264 VAC, and the DC input range is 120-350 VDC.
The converter provides two outputs: 24V and 28V, each rated at 6.7 A.
The operating temperature range is -20°C to 50°C, with derating up to 70°C. The maximum temperature with rear air option is 40°C.
Typical efficiency is 85% at full load, with a range of 70-80% typical depending on load conditions.
It meets EN55022 Level B for conducted and radiated EMI, CISPR 22, EN61000-3-2 for harmonic distortion, and EN60950 for isolation.
The converter includes overload protection on all outputs, remote sense, global inhibit/enable, and input OK and DC OK signals.
The power factor is 0.99 typical, meeting EN61000-3-2 requirements.