The Artesyn Embedded Power MP6-2Q-1E-4NN-05 is an 800W AC/DC converter designed for enclosed applications. It offers a universal input voltage range of 85-264 VAC and 120-350 VDC, operating at frequencies from 47-440 Hz. This converter features four outputs and is suitable for ITE (Commercial) and Medical applications.
Key electrical specifications include an efficiency of 70-80% typical and a power factor of 0.99 typical, meeting EN61000-3-2 harmonic distortion compliance. It provides overload protection, voltage adjustment on all outputs, and remote sense capabilities for outputs greater than 2A. The unit includes features like an Input OK signal, Global DC OK signal, and global/individual module inhibits/enables.
For environmental and safety compliance, it meets various standards including UL1950, CSA22.2 No. 234, IEC950, and EN60950. The operating temperature range is -20°C to 50°C, with derating to 50% at 70°C. It is designed for chassis mounting and utilizes forced air cooling with a field-replaceable fan. Additional features include power factor correction and low leakage options for medical applications.
The input voltage range is 85-264 VAC or 120-350 VDC, with a frequency range of 47-440 Hz.
The MP6-2Q-1E-4NN-05 provides four outputs: 24V, 5V, and two 15V rails, with a total power of 800W.
The operating temperature range is -20°C to 50°C (start at 0°C), with linear derating to 50% load at 70°C.
Yes, it features power factor correction with a typical power factor of 0.99 and meets EN61000-3-2 harmonic distortion requirements.
It meets UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, and EN60950 safety standards, and carries CE marking.
The holdover storage time is 20 ms minimum, independent of input VAC.
It uses an internal DC fan with a fan fail signal, or a customer-provided air option. The fan is field-replaceable.