| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Power Rating | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-2Q-1E-4NL-4NL-00 is a versatile AC/DC converter designed for ITE (Commercial) and Medical applications. This enclosed unit offers a robust 800W power rating and supports a universal input voltage range of 85-264 VAC.
Key electrical specifications include 6 outputs, with features such as adjustable output voltage, power factor correction (PFC), and remote on/off capability. The converter operates efficiently, typically achieving 70-80% efficiency at full load, and meets EN61000-3-2 harmonic distortion compliance. It also provides features like current share on outputs rated 10A or greater and remote sense on outputs greater than 2A.
Designed for reliable operation, the MP6-2Q-1E-4NL-4NL-00 has an operating temperature range of -40°C to 70°C with derating. It is chassis mountable and built to withstand shock and vibration according to Mil-Hdbk 810E standards. The unit includes a low noise, field-replaceable fan for cooling and offers options for customer-provided air.
Safety and compliance are addressed with approvals from CB, CE, CSA, UL, and VDE. The converter also meets CISPR 22 and EN55022 Class B conducted and radiated EMI standards. Special features include input OK and global DC OK signals, module inhibits/enables, and a 2-year warranty.
85-264 VAC or 120-350 VDC, 47-440 Hz.
Standard operation: -20°C to 50°C. With rear air option: -20°C to 40°C max. Derate each output linearly to 50% at 70°C.
The converter has 6 outputs total. One output is specified as 15V at 4A. All outputs are adjustable ±10% and can be set down to 0.5V.
It is approved by CB, CE, CSA, UL, and VDE. It meets EN60950 isolation, EN61000-3-2 harmonic distortion, and CISPR 22/EN55022 Level B for conducted and radiated EMI.
Yes, overload protection on all outputs, remote on/off (global and individual module inhibit/enable), and AC OK signal for early warning before outputs lose regulation.
Forced air cooling with a field-replaceable internal DC fan. An option for customer-provided air is available. A low noise fan and fan fail signal are included.
2 years.