| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-2H-1H-1T-4LF-00 is a versatile AC/DC converter from the MP Series, designed for demanding applications. This enclosed unit offers a power output of up to 800W and features five distinct outputs, including voltages like 5.2V and 12V, with a current rating of 10A.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. It boasts a typical efficiency of 70-80% and a power factor of 0.99, meeting EN61000-3-2 standards. The converter includes features such as adjustable output, power factor correction (PFC), remote on/off capability, and universal input.
Designed for reliability, the MP6-2H-1H-1T-4LF-00 operates within a temperature range of -20°C to 50°C, with derating to 50% at 70°C. It meets stringent safety and EMI standards, including UL, CSA, CE, and VDE approvals, with CISPR 22 and EN55022 Class B compliance for conducted and radiated emissions. The unit is built for chassis mounting.
This converter is well-suited for ITE (Commercial) and Medical applications, offering features like overload protection, remote sense capabilities, and an optional low leakage configuration for medical use. It also includes an input OK signal and global DC OK signal for system monitoring.
The input voltage range is 85-264 VAC or 120-350 VDC.
The operating temperature range is -20°C to 50°C, with linear derating to 50% at 70°C.
The converter is chassis mount and enclosed.
It has 5 outputs, each adjustable down to 0.5V.
Yes, it features active power factor correction with a typical power factor of 0.99.
Overload protection on all outputs, current sharing on outputs ≥10A, remote sense on outputs >2A, and global inhibit/enable.
It is certified to CB, CE, CSA, UL, and VDE standards.