The Artesyn Embedded Power MP6-2E-2Q-1R-00 is a versatile AC DC converter with a power rating of 800W. This enclosed unit is designed for chassis mounting and offers a 28V output voltage.
Key electrical specifications include an input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. It boasts a typical efficiency of 70-80% and a power factor of 0.99 typ., meeting EN61000-3-2 standards. The converter includes features such as adjustable output, power factor correction (PFC), and remote on/off functionality.
Designed for demanding environments, the MP6-2E-2Q-1R-00 operates within a temperature range of -40°C to 70°C with derating. It is suitable for ITE (Commercial) and Medical applications, indicated by its approval agencies including CB, CE, CSA, UL, and VDE.
Additional features include overload protection on all outputs, remote sense for outputs greater than 2A, and a global inhibit/enable function. The unit supports current share on outputs rated at 10A or greater. It also offers a low leakage option for medical applications, with leakage current as low as 300 µA max. @ 240 VAC.
The input voltage range is 85-264 VAC or 120-350 VDC, with a frequency of 47-440 Hz.
The converter is rated for 800W total output power.
It has three outputs: 5V, 24V, and 28V.
The operating temperature range is -20°C to 50°C, with linear derating to 50% output at 70°C.
Yes, it features active power factor correction with a typical power factor of 0.99, meeting EN61000-3-2.
Yes, it supports remote on/off via Global Inhibit/Enable with TTL logic (Logic 1 and Logic 0).
It is approved to CB, CE, CSA, UL, and VDE standards, including UL1950, CSA22.2 No. 234 Level 5, IEC950, and EN60950.