The Artesyn MP6-2E-2L-4LE-00 is a high-power AC/DC converter from the MP6 series, delivering up to 800W. It accepts a wide input voltage range of 85-264 VAC or 120-350 VDC, with a frequency range of 47-440 Hz. The unit provides multiple outputs including 5V and two 12V rails, each adjustable by ±10% minimum.
This converter features active power factor correction with a typical power factor of 0.99, meeting EN61000-3-2 harmonic distortion standards. It includes a CISPR 22 and EN55022 Level B EMI filter, with a low leakage current option of 300 µA maximum. The operating temperature range is -20°C to 50°C, with linear derating to 50% load at 70°C.
The MP6-2E-2L-4LE-00 includes protection features such as a 15A internal input fuse, global inhibit/enable TTL control, and an AC OK early warning signal. It is designed for rack-mount or chassis-mount applications and meets Mil-Hdbk 810E shock/vibration standards.
The input voltage range is 85-264 VAC or 120-350 VDC.
The operating temperature range is -20°C to 50°C, with linear derating to 50% load at 70°C.
It meets CISPR 22 and EN55022 Level B (with low leakage option) and Level A EMI standards.
Yes, it features active power factor correction with a typical power factor of 0.99, meeting EN61000-3-2.
The holdover storage time is 20 ms minimum, independent of input VAC.