| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-2E-1Q-4LL-00 is a configurable AC-DC power supply from the MP Series, delivering up to 800W of power. This enclosed unit features chassis mounting and a universal input voltage range of 85-264 VAC or 120-350 VDC, operating at frequencies from 47-440 Hz.
Key electrical specifications include an efficiency of 85% typical and a power factor of 0.99 typical, meeting EN61000-3-2 standards. It offers multiple outputs, including adjustable voltage and current capabilities, with features like overload protection, remote sense, and global inhibit/enable functions. The power supply also includes an Input OK signal and a Global DC OK signal with status indicator LEDs.
Designed for demanding environments, the MP6-2E-1Q-4LL-00 operates within a temperature range of -40°C to 70°C with derating. It meets various safety and compliance standards including UL, CSA, CE, and VDE. The unit is suitable for ITE (Commercial) and Medical applications, with options for low leakage current for medical use.
Cooling is managed by an internal DC fan or customer-provided air. Special features include current sharing on higher-rated outputs, power factor correction, and a 2-year warranty.
The input voltage range is 85-264 VAC or 120-350 VDC.
This model provides four outputs: 5V, 24V, and two 12V outputs, with a total power rating of 800W.
The operating temperature range is -40°C to +70°C with derating. For startup, it is -20°C to +50°C (start at 0°C). Each output derates linearly to 50% at 70°C.
Yes, it features active power factor correction with a typical power factor of 0.99, meeting EN61000-3-2.
It is approved by CB, CE, CSA, UL, and VDE.
The minimum holdover time is 20 ms, independent of input VAC.
Cooling is provided by an internal DC fan, with an option for customer-provided air. A fan fail signal is included.