| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-2E-1E-4LL-20 is an enclosed AC DC converter designed for chassis mounting. It delivers up to 800W of power and features three outputs, including adjustable voltage and margining capabilities on single output modules.
Key electrical specifications include an input voltage range of 85-264 VAC or 120-350 VDC, with a frequency range of 47-440 Hz. The converter boasts high efficiency, typically 70-80%, and a power factor of 0.99 typ., meeting EN61000-3-2 harmonic distortion compliance. It offers features such as overload protection, remote sense on outputs greater than 2A, and global inhibit/enable functionality.
Environmental considerations include an operating temperature range of -20°C to 50°C (derating applies above 40°C with rear air option) and storage temperatures from -40°C to +85°C. Humidity is rated at 95% non-condensing. The unit supports forced air cooling with a field-replaceable fan.
This AC DC converter is approved by multiple agencies including CB, CE, CSA, UL, and VDE, meeting safety standards like UL1950 and EN60950. It is suitable for ITE (Commercial) and Medical applications, with an optional low leakage configuration available for medical use.
The input voltage range is 85-264 VAC or 120-350 VDC.
The MP6-2E-1E-4LL-20 provides three outputs: 5V and two 12V rails.
The operating temperature range is -20°C to 50°C, with linear derating to 50% at 70°C.
The MP6-2E-1E-4LL-20 has UL1950, CSA22.2 No. 234 Level 5, IEC950, EN60950, and CB certificate approvals.
Yes, it has power factor correction with a typical power factor of 0.99.
The holdover storage time is 20 ms minimum, independent of input VAC.
The typical efficiency is 70-80% at full case load.