| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Overload Protection | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-1F-1L-1Q-1Q-4NN-00 is a versatile AC DC converter belonging to the MP Series. This enclosed unit delivers up to 800W of power and features a chassis mount for easy integration.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. It boasts an efficiency of up to 85% and features power factor correction meeting EN61000-3-2 standards. The converter offers multiple outputs, including adjustable voltage and margining capabilities on single output modules. Special features include overload protection, remote sense on higher current outputs, and an input OK signal.
Designed for demanding environments, the MP6-1F-1L-1Q-1Q-4NN-00 operates within a temperature range of -40°C to 70°C with derating. It complies with various safety and EMI standards, including UL, CSA, CE, and VDE, and meets CISPR 22, EN55022 Curve B for conducted and radiated EMI. The unit is suitable for ITE (Commercial) and Medical applications, with an optional low leakage configuration available for medical use.
Cooling is managed by an internal DC fan, which is field replaceable, or by customer-provided air. The converter also includes features like global and individual module inhibits/enables, and a fan fail signal for enhanced system monitoring.
The input voltage range is 85-264 VAC or 120-350 VDC.
The converter delivers up to 800W total output power.
It has 6 outputs.
The operating temperature range is -20°C to 50°C, with linear derating to 50% load at 70°C.
Yes, it features power factor correction with a typical power factor of 0.99, meeting EN61000-3-2.
It uses forced air cooling with a field-replaceable low-noise fan and includes a fan fail signal.
It meets CISPR 22 and EN55022 Level B for both conducted and radiated EMI.