| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn Embedded Power MP6-1E-1Q-1Q-4LH-NNJ-03 is a high-power AC DC converter from the MP Series, designed for demanding applications. This enclosed unit offers a robust 800W output power with typical efficiencies ranging from 70-80% and a specified 85% efficiency.
Key electrical features include universal input voltage (85-264 VAC / 120-350 VDC), a wide frequency range of 47-440 Hz, and power factor correction meeting EN61000-3-2 standards. It supports adjustable output voltage with a minimum range of ±10% and margining capabilities on single output modules. The converter includes overload protection, remote sense on outputs rated over 2A, and global inhibit/enable functions.
Designed for reliability, it operates within a temperature range of -20°C to 50°C, with derating to 50% at 70°C. Cooling is managed by an internal DC fan or optional customer-provided air. The unit meets various safety and compliance standards including UL, CSA, IEC, VDE, and carries the CE Mark. Its applications include ITE (Commercial) and Medical sectors, with a low leakage option available for medical use.
The MP6-1E-1Q-1Q-4LH-NNJ-03 is a chassis mount device, providing a secure and stable installation in various systems.
85-264 VAC (47-440 Hz) or 120-350 VDC.
-20°C to 50°C (start at 0°C), with linear derating to 50% load at 70°C.
Enclosed chassis mount.
Eight outputs: 5V, two 24V, 12V, and two 6V, adjustable ±10% minimum, with remote sense on outputs >2A and current share on outputs ≥10A.
Internal DC fan (field replaceable) or customer-provided air option.
UL 1950, CSA 22.2 No. 234 Level 5, IEC 950 Class 1, VDE EN60950, BABT, and CE Mark.
Yes, active PFC with 0.99 typical power factor, meeting EN61000-3-2 harmonic distortion requirements.