The Artesyn Embedded Power MP6-1A-1B-1D-1L-4LL-00 is a versatile 800W enclosed AC/DC converter suitable for ITE (Commercial) and Medical applications. This unit features a chassis mount design for easy integration into systems.
Key electrical specifications include a universal input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. It offers an efficiency of 70-80% typical and a power factor of 0.99 typical, meeting EN61000-3-2 standards. The converter provides multiple outputs, including adjustable voltage options and a standby output, with remote sense capabilities on outputs rated greater than 2A.
Environmental and safety certifications include UL, CSA, VDE, CE, and CB reports, ensuring compliance with various industry standards. The operating temperature range is -40°C to 70°C with derating, and it is designed for forced air cooling with a field-replaceable fan. Additional features include overload protection, global inhibit/enable functions, and an Input OK signal.
This model is designed for robust performance and reliability in demanding environments. Its comprehensive feature set and certifications make it a suitable choice for a wide array of commercial and medical equipment designs.
The input voltage range is 85-264 VAC or 120-350 VDC, with a frequency of 47-440 Hz.
The operating temperature range is -20°C to 50°C (start at 0°C), with linear derating of each output to 50% at 70°C.
Typical efficiency is 70-80% at full load (as per the datasheet).
It holds UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, CB Certificate, and CE Mark.
Typical power factor is 0.99, meeting EN61000-3-2 harmonic distortion requirements.
Hold-up time is a minimum of 20 ms, independent of input AC voltage.
Overload protection on all outputs, global inhibit/enable, module enables, and input OK and DC OK signals with LED indicators.