| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Input Voltage | |
| Isolation | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP4-4LL-4LL-4LL-4LL-4LL-00 is a high-performance AC/DC converter from the MP Series, delivering up to 600W of power. This enclosed unit features a chassis mount and offers a universal input voltage range of 85-264 VAC or 120-350 VDC, operating at frequencies from 47-440 Hz.
With 10 outputs, including a primary 12V output capable of 4A, this converter is designed for demanding applications. Key features include adjustable output voltage, power factor correction (PFC) meeting EN61000-3-2, remote sense capabilities on outputs greater than 2A, and overload protection. It also provides an Input OK signal and a Global DC OK signal with status indicator LEDs, along with global and individual module inhibits/enables.
The operating temperature range is -40°C to 70°C with derating, and it meets various safety and EMI standards including UL1950, CSA22.2 No. 234, IEC950, EN60950, and CE Mark. The unit also complies with CISPR 22 and EN55022 Curve B for conducted and radiated EMI. Its dimensions are 254.0mm x 127.0mm x 63.5mm.
This converter is suitable for ITE (Commercial) and Medical applications, offering features like a low leakage option for medical use and a 2-year warranty. Cooling is managed by an internal DC fan or customer-provided air.
The input voltage range is 85-264 VAC or 120-350 VDC.
Each of the 10 outputs provides 12V at 4A.
The operating temperature range is -20°C to 50°C (starting at 0°C), with linear derating to 50% load at 70°C.
It is approved to UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, and carries CE marking.
Yes, it features power factor correction with a typical power factor of 0.99, meeting EN61000-3-2.
It is chassis mount and uses forced air cooling via an internal DC fan or customer-provided air.
Yes, it is approved for medical applications and offers a low leakage option (300 µA max. @ 240 VAC).