| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Input Voltage | |
| Isolation | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP4-2W-1Q-00 is an enclosed AC DC converter designed for ITE (Commercial) and Medical applications. It delivers up to 600W of power with a 24V output voltage and a current rating of 8.5A.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. The converter boasts high efficiency, typically 70-80% at full load, and features power factor correction meeting EN61000-3-2 standards. It supports universal input and includes features such as adjustable output, remote sense, standby output, and overload protection.
This model is chassis mountable and has dimensions of 254.0mm x 127.0mm x 63.5mm. Environmental specifications include an operating temperature range of -20°C to 50°C (derating applies above 40°C) and 95% non-condensing humidity. Safety approvals include CB, CE, CSA, UL, and VDE.
Special features enhance its versatility, including current share on outputs rated 10A or greater, remote sense on outputs greater than 2A, and global/individual module inhibits. It also offers an optional low leakage configuration for medical applications and meets CISPR 22, EN55022 Curve B EMI standards.
The input voltage range is 85-264 VAC (47-440 Hz) or 120-350 VDC.
The output is 24V at 8.5A, providing 600W total power.
The operating temperature is -20°C to 50°C, with derating linearly to 50% load at 70°C. With the rear air option, the maximum is 40°C.
The converter is chassis mount.
Typical efficiency is 70-80% at full load per the datasheet, and 85% per the existing database.
The power factor is 0.99 typical and meets EN61000-3-2 harmonic distortion requirements.
Holdover storage is a minimum of 20 ms, independent of input voltage.