| Category | |
| Manufacturer Name | |
| AEC Qualified | |
| Applications | |
| Approval Agency | |
| Automotive Grade | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Industrial Grade | |
| Input Voltage | |
| Isolation | |
| Length | |
| Medical Grade | |
| Military Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP4-2Q1-1L1-4LQ4-01 is an enclosed AC/DC converter designed for ITE (Commercial) and Medical applications. It delivers up to 600W of power and features four outputs, with a primary voltage of 24V and a current rating of 2A.
This converter supports a wide input voltage range of 85-264 VAC and 120-350 VDC, operating at frequencies from 47-440 Hz. It boasts an efficiency of 85% typical and features power factor correction meeting EN61000-3-2 standards. Key features include adjustable output, remote sense, overload protection, and global inhibit/enable functionality.
The operating temperature range is -40°C to 70°C with derating, and it is designed for chassis mounting. The unit measures 254.0mm x 127.0mm x 63.5mm. Compliance is certified by CB, CE, CSA, UL, and VDE.
Special features include current sharing on outputs rated 10A or greater, remote sense on outputs greater than 2A, and an optional low leakage configuration for medical applications. It also includes an input OK signal and global DC OK signal with status indicator LEDs.
The input voltage range is 85-264 VAC or 120-350 VDC.
The operating temperature range is -20°C to 50°C without derating, and -40°C to 70°C with derating. With the rear air option, the maximum is -20°C to 40°C.
It is an enclosed chassis mount unit with dimensions 254.0mm x 127.0mm x 63.5mm (10.00" x 5.00" x 2.50").
It is approved to CB, CE, CSA, UL, and VDE standards.
Yes, all outputs are adjustable by ±10% minimum.
The typical efficiency is 70-80% at full load.
Yes, it features active power factor correction with a typical power factor of 0.99, meeting EN61000-3-2.