| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Failure Rate | |
| Features | |
| Frequency | |
| Height | |
| Input Voltage | |
| Isolation | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Overload Protection | |
| Power (Watts) | |
| SVHC Present | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP4-2I-1E-LLE-00 is an enclosed AC/DC converter with a power rating of 600W. It accepts a wide input voltage range of 85-264 VAC and 350 VDC, with a frequency range of 47-440 Hz. This model features multiple outputs and is designed for applications in ITE (Commercial) and Medical fields.
Key electrical specifications include a typical efficiency of 85% and a power factor of 0.99 typical, meeting EN61000-3-2 standards. It offers features such as adjustable output, power factor correction, remote sense, and a standby output. The unit operates within a temperature range of -20°C to 50°C, with derating at higher temperatures.
Mechanically, the converter is designed for chassis mounting and has dimensions of 254.0mm x 127.0mm x 63.5mm. It utilizes forced air cooling, with an option for customer-provided air. Safety certifications include UL, CSA, IEC, VDE, BABT, and CE Mark compliance.
Special features include current share on outputs rated 10A or greater, remote sense on outputs greater than 2A, overload protection, and voltage adjustment on all outputs. It also provides an Input OK signal and a Global DC OK signal with status indicator LEDs, along with global and individual module inhibits/enables.
The input voltage range is 85-264 VAC or 120-350 VDC.
It is an enclosed chassis-mount unit.
The operating temperature range is -20°C to 50°C (start at 0°C), with linear derating to 50% at 70°C. With rear air option, maximum is 40°C.
Yes, it has power factor correction, typical 0.99, meeting EN61000-3-2.
It is certified to UL1950, CSA22.2 No. 234 Level 5, IEC950, EN60950, and BS 7002, with CE marking.
The holdover storage time is 20 ms minimum, independent of input VAC.
It uses forced air cooling with an internal field-replaceable DC fan, or customer-provided air option.