| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Failure Rate | |
| Features | |
| Frequency | |
| Halogen Free | |
| Height | |
| Industrial Grade | |
| Input Voltage | |
| Isolation | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| SVHC Present | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP4-2F-1F-00 is a versatile AC/DC converter from the MP Series, delivering up to 600W of power. This enclosed unit features a chassis mount design and provides two outputs, with a primary voltage of 5.2V and a current rating of 35A. It operates within a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz.
Key features include adjustable output, power factor correction (PFC), remote sense capabilities, a standby output, and universal input. The converter meets EN61000-3-2 harmonic distortion compliance and CISPR 22, EN55022 Curve B for conducted and radiated EMI. It also supports European CE Mark requirements and has approvals from CB, CE, CSA, UL, and VDE.
Designed for demanding environments, the MP4-2F-1F-00 operates between -40°C and 70°C with derating. Its dimensions are 254.0mm x 127.0mm x 63.5mm. Applications include ITE (Commercial) and Medical sectors, benefiting from features like overload protection and remote sense on outputs rated greater than 2A.
The input voltage range is 85-264 VAC or 120-350 VDC, with a frequency of 47-440 Hz.
The operating temperature range is -20°C to 50°C (start at 0°C) with linear derating to 50% load at 70°C. Storage temperature is -40°C to +85°C.
Dimensions are 254.0 x 127.0 x 63.5 mm (10.00 x 5.00 x 2.50 inches). It is chassis mount and enclosed.
The converter has two outputs, each rated at 5.2V. Total power is 600W.
Approvals include CB, CE, CSA, UL, VDE. It meets EN55022 Level B, CISPR 22, and EN61000-3-2 harmonic distortion standards.
Efficiency is rated 85% from the existing database, and 70-80% typ. under full load per the datasheet.