| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Industrial Grade | |
| Input Voltage | |
| Isolation | |
| Length | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP4-1Q-1Q-10 is an enclosed AC/DC converter designed for reliable power conversion in demanding environments. This unit offers a total power output of 600W, with a primary output voltage of 60V and a current rating of 8.5A. It supports universal input voltage ranges from 85-264 VAC and 120-350 VDC, operating at frequencies between 47-440 Hz.
Key features include adjustable output voltage, power factor correction (PFC), remote sense capabilities, and a standby output. The converter is designed for chassis mounting and has an operating temperature range of -40°C to 70°C with derating. Its dimensions are 254.0mm x 127.0mm x 63.5mm.
This AC/DC converter is suitable for applications in ITE (Commercial) and Medical sectors, indicated by its features and compliance certifications including CB, CE, CSA, UL, and VDE. It meets stringent EMI standards such as CISPR 22 and EN55022 Level B, ensuring minimal interference in sensitive systems. Additional features like overload protection and global inhibit/enable provide robust operational control.
The input voltage range is 85-264 VAC or 120-350 VDC, with a frequency of 47-440 Hz.
It is an enclosed chassis mount package with dimensions 254.0 mm x 127.0 mm x 63.5 mm.
The operating temperature range is -20°C to 50°C, with linear derating to 50% load at 70°C. Storage temperature is -40°C to +85°C.
The converter provides dual outputs of 24V and 60V, with a total current of 8.5A and total power of 600W.
It is approved to UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, and carries CE Mark. CB certificate and report are available.
Yes, it features power factor correction with a typical power factor of 0.99, meeting EN61000-3-2 harmonic distortion requirements.
Typical efficiency is 85% at full load, with a range of 70-80% typ. depending on conditions.