| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Input Voltage | |
| Isolation | |
| Length | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP4-1E-1E-1E-1E-00 is an enclosed AC DC converter with a power rating of 600W. It features a universal input voltage range of 85-264 VAC and a frequency range of 47-440 Hz. This model offers four outputs, with a primary 5V output and a current rating of 35A, delivering a total power of 600W. The efficiency is typically 85%.
Designed for versatility, this converter includes features such as adjustable output, power factor correction (PFC), remote sense, and a standby output. It is suitable for ITE (Commercial) and Medical applications. The unit is designed for chassis mounting and has dimensions of 254.0mm x 127.0mm x 63.5mm.
Environmental and safety compliance includes UL, CSA, CE, VDE, and CB certifications. The operating temperature range is -40°C to 70°C with derating, and storage temperature is -40°C to +85°C. The converter also meets EN61000 immunity standards and CISPR 22, EN55022 Class B conducted/radiated EMI requirements.
The input voltage range is 85-264 VAC (47-440 Hz) and 120-350 VDC.
It is an enclosed chassis mount unit.
The operating temperature range is -20°C to 50°C with linear derating to 50% load at 70°C; storage from -40°C to 85°C.
Yes, it features active power factor correction with a typical power factor of 0.99, meeting EN61000-3-2 harmonic distortion requirements.
The converter provides overload protection on all outputs, remote sense on outputs above 2A, voltage adjustment, and global inhibit/enable. It also includes input OK and DC OK signals.
It is approved to UL1950, CSA22.2 No. 234 Level 5, EN60950 (VDE), IEC950 Class 1, and carries CE and CB marks. It also meets BABT/EN60950.
The hold-up time is 20 ms minimum, independent of input voltage.