The Artesyn Embedded Technologies MP4-1D-1E-1P-03 is a configurable AC DC power supply with a power rating of 600W. It offers a universal input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz.
This enclosed unit features a chassis mount type and provides three outputs, including 3.3V and 60V. The maximum output current for the third output is 10.5A, while the first two can handle up to 35A each. Key electrical features include an efficiency of 85%, power factor correction (PFC) meeting EN61000-3-2 standards, and adjustable output voltage with margining capabilities.
Designed for demanding environments, the MP4-1D-1E-1P-03 operates within a temperature range of -40°C to 70°C with derating. It includes features such as remote sense, overload protection, and a standby output. Compliance is met with agencies including CB, CE, CSA, UL, and VDE.
Physical dimensions are 254.0mm in length, 127.0mm in width, and 63.5mm in height. The power supply is suitable for ITE (Commercial) and Medical applications.
The universal input range is 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz.
The converter provides dual outputs: 3.3V at 35A and 60V at 35A.
The operating temperature range is -40°C to 70°C with linear derating to 50% at 70°C. Also specified as -20°C to 50°C at 0°C start.
The converter is enclosed and chassis-mounted. Dimensions are 254.0 x 127.0 x 63.5 mm (10 x 5 x 2.5 inches).
Typical efficiency is 70-80% under full load, with a separate reported value of 85% at unspecified conditions.
Yes, overload protection is provided on all outputs.
It meets CISPR 22 and EN55022 Level B for conducted and radiated EMI, with a low-leakage option for medical applications.