The Artesyn Embedded Power MP4-1A-1E-1L-4EC-4LD-00 is a configurable AC DC power supply from the MP Series, designed for ITE (Commercial) and Medical applications. This enclosed unit offers a total power output of 600W and features 7 outputs, with adjustable voltage and margining capabilities on single output modules.
Key electrical specifications include an input voltage range of 85-264 VAC or 120-350 VDC, a frequency of 47-440 Hz, and an efficiency typically between 70-80%, with a rated efficiency of 85%. It incorporates power factor correction meeting EN61000-3-2 standards and offers features like remote sense on outputs greater than 2A, overload protection, and global inhibit/enable functions.
Mechanically, the unit is designed for chassis mounting and measures 254.0mm x 127.0mm x 63.5mm. It operates within a temperature range of -40°C to 70°C with derating. Safety approvals include CB, CE, CSA, UL, and VDE.
The power supply meets various EMI standards, including CISPR 22 and EN55022 Level B. A low leakage option is available for medical applications, reducing leakage current to 300 µA max. @ 240 VAC.
It accepts a universal input of 85-264 VAC or 120-350 VDC across 47-440 Hz.
The module delivers seven independent DC outputs with adjustable voltage ranges.
It operates from -40°C to 70°C, requiring linear derating to 50% load at 70°C.
Yes, it features a standard CISPR 22 and EN55022 Level B EMI filter for conducted and radiated emissions.
It is certified to UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, VDE EN60950, and carries the CE mark.
The enclosure uses forced air cooling via an internal DC fan or optional customer-provided rear airflow.
The module provides TTL-based global and individual inhibit/enable inputs along with AC OK and global DC OK status signals.