| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Input Voltage | |
| Isolation | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP4-1A-1D-1E-4LE-JIB-00 is a configurable AC DC converter designed for ITE (Commercial) and Medical applications. This enclosed unit offers a power output of 600W and supports a wide input voltage range of 85-264 VAC or 120-350 VDC.
Key electrical specifications include an efficiency of up to 85% and a power factor of 0.99 typical, meeting EN61000-3-2 harmonic distortion compliance. It features 8 outputs with adjustable voltage and remote sense capabilities on outputs rated over 2A, along with overload protection. Special features include power factor correction, input and global DC OK signals, and global/individual module inhibits.
Mechanically, the converter is designed for chassis mounting and has dimensions of 254.0mm x 127.0mm x 63.5mm. It operates within a temperature range of -20°C to 50°C, with derating applied at higher temperatures. Cooling is managed by an internal DC fan or optional customer-provided air.
Safety certifications include CB, CE, CSA, UL, and VDE, adhering to standards such as UL1950, CSA22.2 No. 234, IEC950, and EN60950. The unit also offers options for low leakage current, making it suitable for medical applications.
The operating temperature range is -20°C to 50°C, with derating applied at higher temperatures.
The dimensions are 254.0mm (Length) x 127.0mm (Width) x 63.5mm (Height).
It complies with UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, and BS 7002.
The typical efficiency is between 70-80% at full case load, and up to 85% is listed in other specifications.
The power factor is typically 0.99 and meets EN61000-3-2 harmonic distortion compliance.
Yes, it features overload protection on all outputs.
It uses internal DC fan cooling or an optional customer-provided air system.