The Artesyn Embedded Power MP1-3Y-3Q-1Q-00 is a high-power enclosed AC DC converter with a total output power of 1200W. This model features three outputs, with a primary output voltage of 60V and a current rating of 8.5A. It is designed for chassis mounting, making it suitable for integration into various systems.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 47-440 Hz frequency. The converter boasts high efficiency, typically 70-80%, and a power factor of 0.99, meeting EN61000-3-2 standards. It offers features such as adjustable output, remote sense, and a standby output. The operating temperature range is -40°C to 70°C with derating.
Designed for demanding applications, this AC DC converter is suitable for ITE (Commercial) and Medical use. It complies with various safety and EMI standards, including CB, CE, CSA, UL, and VDE, and meets CISPR 22 and EN55022 Level B for radiated and conducted EMI. The dimensions are 279.4mm x 203.2mm x 63.5mm.
Additional features include overload protection, voltage adjustment on all outputs, and a 2-year warranty. The unit also supports global inhibit/enable functionality.
The input voltage range is 85-264 VAC or 120-350 VDC at 47-440 Hz.
The MP1-3Y-3Q-1Q-00 has three outputs with a 60V main output rated at 8.5A, providing 1200W total power.
The operating temperature range is -20°C to 50°C with start at 0°C, and storage temperature from -40°C to +85°C.
The converter carries CB, CE, CSA, UL, and VDE approvals.
Efficiency is 70-80% typical at full case load.
Holdover storage is 20 ms minimum, independent of input VAC.
All outputs have an adjustment range of ±10% minimum, with margining of ±4-6% nominal.