| Category | |
| Manufacturer Name | |
| AEC Qualified | |
| Applications | |
| Approval Agency | |
| Automotive Grade | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Industrial Grade | |
| Input Voltage | |
| Isolation | |
| Length | |
| Medical Grade | |
| Military Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP1-3E-2F-1L-1L-00 is a high-power enclosed AC DC converter designed for demanding applications. With a total output power of 1200W and four distinct outputs, this unit offers versatility for various system configurations.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. The converter boasts typical efficiencies of 70-80% and a power factor of 0.99, meeting EN61000-3-2 standards. It provides features such as adjustable output, remote sense, and power factor correction.
Mechanically, the unit is designed for chassis mounting with dimensions of 279.4mm x 203.2mm x 63.5mm. It operates within a temperature range of -40°C to 70°C with derating. Safety approvals include CB, CE, CSA, UL, and VDE, making it suitable for ITE (Commercial) and Medical applications.
Additional features include overload protection, voltage adjustment on all outputs, and global inhibit/enable functionality. The converter also supports low leakage options for medical applications and meets CISPR 22, EN55022 Curve B conducted/radiated EMI standards.
The input voltage range is 85-264 VAC or 120-350 VDC.
The operating temperature range is -40°C to 70°C with derating (derate each output linearly to 50% at 70°C), and -20°C to 50°C (start at 0°C) with rear air option.
The converter is an enclosed chassis mount unit with dimensions 279.4 x 203.2 x 63.5 mm.
It has four outputs.
The output configuration is 5V, 5.2V, and two 12V rails.
Yes, it features active power factor correction with a typical power factor of 0.99 and meets EN61000-3-2.
It is approved by CB, CE, CSA, UL, and VDE.