The Artesyn Embedded Power MP1-3D-3D-00 is a high-power AC/DC converter from the MP Series, delivering up to 1200W. This enclosed unit features a universal input voltage range of 85-264 VAC and provides two 3.3V outputs. Designed for reliability and versatility, it includes features such as adjustable output, power factor correction, remote sense, and a standby output.
With a chassis mount type, this converter is suitable for integration into various systems. Its dimensions are 279.4mm x 203.2mm x 63.5mm. The operating temperature range is -40°C to 70°C with derating, and it meets stringent safety and environmental standards including UL, CSA, CE, and VDE approvals.
Key features include overload protection, voltage adjustment on all outputs, and options for low leakage current, making it suitable for medical applications. The unit also supports global and individual module inhibits/enable functions, along with input OK and global DC OK signals for system monitoring.
The input voltage range is 85-264 VAC (47-440 Hz) or 120-350 VDC.
It provides two outputs of 3.3V at 60A each for a total power of 1200W.
The converter operates from -20°C to 50°C, with linear derating to 50% load at 70°C. With the rear air option the maximum is 40°C.
It is certified to UL1950, CSA22.2 No. 234 Level 5, IEC950 Class 1, EN60950, and EN 60950/BS 7002. It carries CB, CE, CSA, UL, and VDE marks.
Yes, typical power factor is 0.99 and it meets EN61000-3-2 harmonic distortion requirements.
It uses forced air cooling with an internal DC fan (field replaceable). An option for customer-provided air is available.
Remote sense is available on all outputs rated greater than 2A. Current sharing is supported on all outputs with ratings of 10A or greater.