| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Industrial Grade | |
| Input Voltage | |
| Isolation | |
| Length | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP1-3D-1A-1E-1L-LNE-03 is a high-power AC DC converter designed for ITE (Commercial) and Medical applications. This enclosed unit offers a total power output of 1200W and features 7 distinct outputs, including adjustable voltage options.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. The converter boasts an efficiency of 70-80% typical and a power factor of 0.99 typical, meeting EN61000-3-2 standards. Special features include current share on outputs rated 10A or greater, remote sense on outputs greater than 2A, overload protection, voltage adjustment on all outputs, and margining on single output modules. It also provides Input OK and Global DC OK signals with status indicator LEDs, along with global and individual module inhibits/enables.
Environmental and safety certifications include CB, CE, CSA, UL, and VDE compliance. The operating temperature range is -20°C to 50°C (derating applies above 40°C with rear air option), with a storage temperature range of -40°C to +85°C. The unit is designed for chassis mounting and has dimensions of 279.4mm x 203.2mm x 63.5mm.
This converter is suitable for demanding applications requiring reliable power conversion and multiple voltage outputs. Its robust design and comprehensive feature set make it a versatile choice for various industrial and medical equipment.
85-264 VAC or 120-350 VDC.
Enclosed chassis mount.
-20°C to 50°C (start @ 0°C), with derating up to 70°C. With rear air option, -20°C to 40°C.
1200W.
7 outputs.
70-80% typical at full load, up to 85% typical.
CB, CE, CSA, UL, VDE.