| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Input Voltage | |
| Isolation | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Artesyn Embedded Power MP1-3C-2F-2F-00 is a high-power enclosed AC/DC converter with a total output of 1200W. This model features three distinct outputs, designed to provide versatile power solutions for demanding applications.
Key electrical specifications include a wide input voltage range of 85-264 VAC and 120-350 VDC, with a frequency range of 47-440 Hz. It boasts a typical efficiency of 70-80% and a power factor of 0.99, meeting EN61000-3-2 standards. The unit offers adjustable output voltage with a minimum range of ±10% and margining of ±4-6% nominal. Special features include remote sense on outputs greater than 2A, overload protection, and power factor correction.
Designed for robust operation, the MP1-3C-2F-2F-00 operates within a temperature range of -20°C to 50°C, with derating to 50% at 70°C. It meets stringent safety and EMI standards, including UL, CSA, CE, and VDE approvals, with CISPR 22 and EN55022 Level 'B' EMI filtering. The converter is suitable for ITE (Commercial) and Medical applications, offering features like adjustable output, PFC, remote sense, and a standby output.
This converter utilizes chassis mounting for secure integration into systems. Its dimensions are 279.4mm x 203.2mm x 63.5mm (11.00" x 8.00" x 2.50"). Cooling is managed by an internal DC fan or an optional customer-provided air solution. The unit also includes an Input OK signal and a Global DC OK signal with a status indicator LED.
85-264 VAC or 120-350 VDC.
-20°C to 50°C, derating to 50% at 70°C.
Chassis mount, 279.4 x 203.2 x 63.5 mm (11 x 8 x 2.5 in).
Three outputs: 3V and two 5.2V, each adjustable ±10%.
CB, CE, CSA, UL, VDE.
ITE (commercial) and medical.
70-80% typical at full load.