| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Input Voltage | |
| Isolation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage |
The Artesyn MP1-2Q-2W-1L-4LL-4NN-0R is a 1200W enclosed AC/DC converter offering seven independently adjustable outputs. It accepts a universal input of 85-264 VAC or 120-350 VDC at 47-440 Hz, with a typical efficiency of 70-80% and power factor correction above 0.99 meeting EN61000-3-2. The converter includes active power factor correction, remote sense on outputs over 2A, current sharing on outputs over 10A, and global inhibit/enable with TTL logic. Each output provides voltage adjustment and margining.
It is chassis-mount with dimensions 279.4mm x 203.2mm x 63.5mm and cooled by an internal DC fan or customer-provided air. The operating temperature range is -20°C to 50°C (start at 0°C), with linear derating to 50% load at 70°C. It features overload protection, input OK and DC OK signals, a fan fail signal, and a low noise fan. A low leakage option is available for medical applications.
The converter is approved to CB, CE, CSA, UL, and VDE standards for both ITE (commercial) and medical applications. It meets CISPR 22/EN55022 Level B for conducted and radiated EMI, EN61000-3-2 for harmonics, and EN61000 immunity standards. Isolation meets EN60950. Optional modules for VME timing and system DC OK are available.
The operating temperature range is -20°C to 50°C (starting at 0°C), with linear derating to 50% load at 70°C. The storage temperature range is -40°C to +85°C.
It accepts 85-264 VAC or 120-350 VDC with a frequency range of 47-440 Hz.
Typical efficiency is 70-80% at full load, with a power factor of 0.99 typical meeting EN61000-3-2.
Minimum hold-up time is 20 ms independent of input VAC. An AC OK signal provides >5 ms early warning before outputs lose regulation.
The chassis-mount enclosed unit measures 279.4mm (11.00") L x 203.2mm (8.00") W x 63.5mm (2.50") H.
It is approved to CB, CE, CSA, UL, and VDE standards for ITE (commercial) and medical applications.
Yes, remote sense is available on all outputs rated >2 A, and current sharing on outputs ≥10 A. Other features include global inhibit/enable, margining, and voltage adjustment on all outputs.