| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Frequency | |
| Height | |
| Length | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Standard Number | |
| Type | |
| Voltage | |
| Width |
The LCC600-48U-4P is a 600W AC-DC converter from Artesyn Embedded Power, part of the LCC600 series. It offers a single output of 48 VDC at 12.5 A. This model features the U suffix, indicating compliance with medical safety standards with 2xMOPP isolation and low leakage current.
Universal input range 90-264 Vac with frequency 47-63 Hz. Efficiency up to 93.3% typical at 230 Vac. Power factor 0.99 typical. Hold-up time 20 ms minimum at full load. Isolation: 4000 Vac primary to secondary (2xMOPP), 1500 Vac primary to chassis, and 1500 Vac secondary to chassis.
Operating baseplate temperature range -40°C to 85°C. Designed for conduction cooling, typically requiring a heatsink or cold plate. Suitable for medical, industrial, and telecom applications requiring high reliability and low noise.
90-264 Vac for U suffix models.
48 VDC at 12.5 A.
-40°C to 85°C baseplate.
4000 Vac primary to secondary (2xMOPP), 1500 Vac primary to chassis, and 1500 Vac secondary to chassis.
Yes, the U suffix model features 2xMOPP isolation and low leakage current per IEC60601-1.
Up to 93.3% typical at 230 Vac.
0.99 typical, indicating active PFC.